MIDI Implementation
The VS-2480/2480CD can transfer and receive the internal parameters information using
system exclusive messages, and also can be controlled by the external devices using system
exclusive message.
The VS-2480/2480CD can transmit and receive Universal System Exclusive messages, Data
Request (RQ1) and Data set (DT1) as the System Exclusive Message.
❍About Model ID
The Model ID of the VS-2480/2480CD is 00H,40H as for Data Request (RQ1) and Data set
(DT1). The VS-2480/2480CD also can receive 00H,40H (VS-2480/2480CD) and 00,36H (VE-
7000).
❍About Device ID
System Exclusive messages are not assigned to any particular MIDI channel. Instead, they
have their own special control parameter called device ID.
The roland system exclusive messages use device IDs to specify multiple VS-2480/2480CD
units.
The VS-2480/2480CD sends system exclusive messages using 00H-1FH, and receives the
system exclusive messages whose device ID is same as its device ID and 7FH.
the value of the device ID is the value set on the UTILITY-MIDI screens DEVICE ID minus
one.
●Universal System Exclusive message
❍INQUIRY MESSAGE
Status
Data byte
F0H
7EH,Dev,06H,01H
Byte
Description
F0H
Status of System Exclusive Message
7EH
Universal System Exclusive message Non Real-time header
Dev
Device ID (or 7FH)
06H
General Information (sub-ID #1)
01H
Identify Request (sub-ID #2)
F7H
EOX (End of System Exclusive Message)
The message is used to request the particular information of the VS-2480/2480CD.
The VS-2480/2480CD does not transmit the message.
If the VS-240 received the message and the device ID of the message is same as its device.
ID or 7FH, the VS-2480/2480CD transmits the following Identify Reply message.
❍Identity Reply
Status
Data Byte
F0H
7EH,Dev,06H,02H,41H,mmH,mmH,
00H,00H,00H,00H,ssH,ssH
Byte
Description
F0H
Status of System Exclusive Message
7EH
Universal System Exclusive Non Real-time Header
Dev
Device ID
06H
General Information (sub-ID #1)
02H
Identify Request (sub-ID #2)
41H
Manufacturer ID (Roland)
mmH mmH
Device Family Code (VS-2480/2480CD)
00H 00H
Device Family No.
00H
00H
ssH ssH
Software Revision Level
F7H
EOX (End of Exclusive Message)
The value of the device family code is according to the value of SYSTEM parameters "MIDI
Model ID."
When VS-2480/2480CD, the value of the device family code is 40H 01H.
❍MIDI Time Code
Status
Data Byte
F0H
7FH,Dev,01H,01H,hr,mn,sc,fr
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Real-time Header
Dev
Device ID
01H
MIDI Time Code
01H
MIDI Time Code Full Message
hr
Type/Hour (0yyzzzzz)
yy: Time Code Type
mn
Minutes (0–59)
sc
Second (0–59)
fr
Frame (0–29)
F7H
EOX (End of Exclusive Message)
100
Status
F7H
Status
F7H
Status
F7H
0=24 Frame/Sec
1=25 Frame/Sec
2=30 Frame/Sec (Drop)
3=30 Frame/Sec (Non-Drop)
❍MIDI Machine Control Commands
Status
Data Byte
F0H
7FH,Dev,06H,aaH, ..., bbH
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Real-time Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
aaH
Command
:
:
bbH
Command
F7H
EOX (End of Exclusive Message)
(*) see "3. MIDI Machine Control."
●Data Transfer (RQ1,DT1)
❍Data Request (RQ1)
Status
Data Byte
F0H
41H,Dev,mmH,mmH,11H,
aaH,bbH,ccH,ddH, ssH,ssH,ssH,ssH,Sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 40H
Model ID (VS-2480/2480CD)
11H
Command ID (RQ1)
aaH
Address MSB
bbH
Address
ccH
Address
ddH
Address LSB
ssH
Data MSB
ssH
Data
ssH
Data
ssH
Data LSB
Sum
Check Sum
F7H
EOX (End of Exclusive Message)
❍Data Set (DT1)
<Model ID = 00H 40H (VS-2480/2480CD)>
Status
Data Byte
F0H
41H,Dev,mmH,mmH,12H,
aaH,bbH,ccH,ddH, ..., eeH,Sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 40H
Model ID (VS-2480/2480CD)
12H
Command ID (DT1)
aaH
Address MSB
bbH
Address
ccH
Address
ddH
Address LSB
eeH
Data
Sum
Check Sum
F7H
EOX (End of Exclusive Message)
<Model ID = 00H 36H (VE-7000)>
Status
Data Byte
F0H
41H,Dev,mmH,mmH,12H,
aaH,bbH,ccH,ddH, ..., eeH,Sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 36H
Model ID (VE-7000)
12H
Command ID (DT1)
aaH
Address MSB
bbH
Address
ccH
Address LSB
ddH
Data
Sum
Check Sum
F7H
EOX (End of Exclusive Message)
❍The message is transmitted under the following condition.
If the device ID on the message is same as that of the receive device, and the address on the
message correspond to the specified parameter base address, the received data are stored
form the specified parameter base address.
If the interval of received messages is shorter than 25 msec, the VS-2480/2480CD can not
work the receive message procedure correctly.
Status
F7H
Status
F7H
Status
F7H
Status
F7H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vs-2480cd

Table of Contents