Command details
Commands transmitted from the M-400 to the control computer
ack: Active reply
Function
Transmitted following successful reception.
Syntax
ack (06H) (Command syntax: type 0)
ERR: Error
Function
Transmitted when a problem occurred in the M-400 in response to a command sent from the
control computer.
Syntax
stxERR:a; (Command syntax: type 2)
a: Error number
0 (Syntax error)
Transmitted when the command syntax was incorrect.
2 (Busy error)
The M-400 is busy and cannot process the command.
5 (Out of range error)
The parameter of the received command was out of range.
6 (Other error)
Some other error has occurred. This will be transmitted if the M-400 was unable to correctly
process the command.
Note: If one of these commands occurs, the command that was sent to the M-400 immediately prior to this will be ignored.
Xon (11H) / Xoff (13H): Handshaking commands
Function
Specifies whether transmission is possible. These are used for handshaking.
Syntax
Xon is 11H only (transmission is possible)
Xoff is 13H only (transmission is not possible)
26
1PS