Flq: Filter Request; Eqq: Eq Request - Roland M-400 Reference Manual

Live mixing console rs-232c reference
Hide thumbs Also See for M-400:
Table of Contents

Advertisement

FLQ: Filter request

Function
Requests the filter on/off setting.
Syntax
stxFLQ:a; (Command syntax: type 2)
a: Channel selection (I1–I48, U1–U24)
<Ex.> stxFLQ:I1;
Requests the CH1 filter on/off setting.
Command returned by the M-400
Syntax
stxFLS : a , b ; (Command syntax: type 2)
a: Channel number (I1–I48, U1–U24)
b: On/off
0 (Off)
1 (On)
<Ex.> stxFLS:I1,0;
Reports that the CH1 filter is off.
Note: If you select a stereo-linked input channel, the same value will be returned for L or R.
Note: If you specify the following parameters, the M-400 will return an ERR command (stxERR:5;) and will ignore your
command.
• If you specify AX1–AX16, MAL, MAR or DCA1–DCA8
• If you specify U1–U24 that is assigned to the above

EQQ: EQ request

Function
Requests the on/off setting of the four-band EQ.
Syntax
stxEQQ:a; (Command syntax: type 2)
a: Channel selection (I1–I48, AX1–AX16, MAL, MAR, U1–U24)
<Ex.> stxEQQ:I1;
Requests the on/off setting of the CH1 four-band EQ.
Command returned by the M-400
Syntax
stxEQS:a,b; (Command syntax: type 2, U1–U24)
a: Channel number (I1–I48, AX1–AX16, MAL, MAR)
b: On/off
0 (Off)
1 (On)
<Ex.> stxEQS:I1,0;
Reports that the CH1 four-band EQ is off.
Note: If you're specifying the MAIN channel, you can specify either the L or R channel, since the MAIN L/R channels are
stereo-linked.
Note: If you specify a stereo-linked input channel or AUX channel, the same value will be returned for L or R.
Note: If you specify the following parameters, the M-400 will return an ERR command (stxERR:5;) and will ignore your
command.
• If you specify DCA1–DCA8
• If you specify U1–U24 that is assigned to the above
Command details