Parameter Address Map; System Exclusive Messages - Roland FP-4 Midi Implementation Manual

Roland fp-4: supplementary guide
Hide thumbs Also See for FP-4:
Table of Contents

Advertisement

MIDI Implementation
❍Effect 3 (Chorus Send Level) (Controller number 93)
Status
2nd bytes
BnH
5DH
n = MIDI channel number:
vv = Control value:
●Program Change
Status
2nd bytes
CnH
ppH
n = MIDI channel number:
pp = Program numbe:
●Pitch Bend Change
Status
2nd byte
EnH
llH
n = MIDI channel number:
mm, ll = Pitch Bend value:
■System Realtime Message
●Realtime Clock
Status
F8H
●Active sensing
Status
FEH
* This will be transmitted constantly at intervals of approximately 250 ms.

■System exclusive messages

❍Identity Reply
Status
Data byte
F0H
7EH, 10H, 06H, 02H, 41H, 42H, 00H, 00H, 16H, 04H, 01H,
00H, 00H
F0H
7EH, 10H, 06H, 02H, 41H, 42H, 00H, 00H, 16H, 05H,
01H, 00H, 00H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (universal non-realtime message)
10H
Device ID (use the same as the device ID of Roland)
06H
Sub ID#1 (General Information)
02H
Sub ID#2 (Identity Reply)
41H
ID number (Roland)
42H
Device family code (LSB)
00H
Device family code (MSB)
00H
Device family number code (LSB)
16H
Device family number code (MSB)
04H(05H)
Software revision level
01H
Software revision level
00H
Software revision level
00H
Software revision level
F7H
EOX (End of Exclusive)
8
3rd byte
vvH
0H-FH (ch.1-ch.16)
00H-7FH (0-127)
0H-FH (ch.1-ch.16)
00H-7FH (prog.1-prog.128)
3rd bytes
mmH
0H-FH (ch.1-ch.16)
00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
Status
F7H [FP-7]
F7H [FP-4]

3. Parameter Address Map

42H)
This map indicates address, size, Data (range), Parameter, Description, and Default Value of
parameters which can be transferred using and "Data set 1 (DT1)."
All the numbers of address, size, Data, and Default Value are indicated in 7-bit
Hexadecimal-form.
■Address Block map
An outlined address map of the Exclusive Communication is as follows;
Address (H)
Block
40 00 00 +------------------------------------+
| SYSTEM PARAMETERS
40 01 3F +------------------------------------+
40 1x 00 +------------------------------------+
| PART PARAMETERS
|
(x = 0-F)
40 2x 5A +------------------------------------+
41 m0 00 +------------------------------------+
| SRUM SETUP PARAMETERS
|
(m = 0-1)
41 m8 7F +------------------------------------+
48 00 00 +------------------------------------+
| SYSTEM PARAMETERS
48 01 10 +------------------------------------+
| PART PARAMETERS
48 1D 0F +------------------------------------+
49 m0 00 +------------------------------------+
| DRUM SETUP PARAMETER
|
(m = 0-1)
49 mE 17 +------------------------------------+
There are two ways in which GS data is transmitted: Individual Parameter Transmission in
which individual parameters are transmitted one by one, and Bulk Dump Transmission in
which a large amount of data is transmitted at once.
(Model ID =
|Individual
|Individual
|
|Individual
|
|Bulk
|Bulk
|Bulk
|