Parameter reference (LUI)
9.2 Setup (2.)
Short Shot Enabled (2.12.2.6.)
Enables/disables short shot.
Options
Short Echo Threshold (2.12.2.7.)
Determines which echoes are evaluated by software
Values
Short Shot Range (2.12.2.8.)
Enter the maximum distance in Units (Page 172) to be measured using short shot echoes.
Values
This feature is automatically altered when Transducer (Page 174) is altered.
Short Shot Floor (2.12.2.9.)
Enter the minimum echo strength, in dB above 1 uV, derived from a short shot to be
considered for evaluation.
Values
226
*
Range: 0 ... 99
Default: 10
Range: 0 ... 2 m or equivalent, depending on Units (Page 172)
Preset: 1.000
Range: 0 ... 100
Preset: 50
ENABLED
DISABLED
Operating Instructions, 04/2021, A5E33329501-AG