Preparing for Operation
Note 2. The DIP switch is located inside the Inverter. Use this switch to change the set-
ting when frequency references are to be input in terms of amperage (4 to 20
mA). For details, refer to Section 7-2 Frequency Reference by Amperage Input.
For voltage input, never set the DIP switch to ON. Doing so may damage the
equipment.
n03
Interruption Mode Selection
Setting range
This constant is used to specify the interruption mode when the STOP/RESET Key is
pressed or the operation command is OFF.
Value
0
Frequency deceleration stop
1
Free running
Example of Frequency Deceleration Stop
Output frequency
Forward rotation
(Reverse rotation)
Operation command
Example of Free Running
Forward rotation
(Reverse rotation)
Operation command
Note This constant is available for models with a PROM number (software version) of
"200" or higher.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
0, 1
Deceleration time 1
ON
OFF
Output frequency
ON
OFF
Factory setting 0
Description
(n21)
Minimum output frequency determined
with constant set in n29: Factory-set to
1.5 kHz
Time
Interruption DC control time determined
with constant set in n47: Factory-set to 0.5
second
Inertia of motor
Chapter 4
Time
4-13