Omron SYSDRIVE 3G3EV-AB004-CE User Manual page 47

Compact low-noise inverter
Table of Contents

Advertisement

Preparing for Operation
Note MA is turned on when the difference between the reference frequency and the
output frequency falls within 2 Hz. MA is turned off when the difference exceeds
±4 Hz.
Example of Operation
Output
frequency
Frequency
matching (for MA)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Reference frequency
Detection range
±2 Hz
Chapter 4
Release range
±4 Hz
4-15