Protection class:
Software:
Operating temperature:
Power reserve:
Time accuracy (typical):
Rated impulse voltage:
Pollution degree:
Contact:
Incandescent lamp load:
Halogen lamp load:
Fluorescent lamp load: uncorrected
series-corrected:
parallel-corrected:
Compact fluorescent lamps (EVG):
LED lamps (< 2 W):
LED lamps (> 2 W):
Bluetooth OBELISK top3:
– Protection rating:
– Temperature:
– Range:
L The time switch display is only fully functional at tempera-
tures from +5 °C ... +55 °C.

Cleaning and service

Only use a dry, soft cloth to clean the device surface.
Do not use any cleaning agents or solvents.
Disposal
Dispose of the device separately from domestic
waste at an official collection point.

8. Dimensional drawings

69,2
35,8
63,7
52,9*
60*
76,2*
II in accordance with
EN 60730-1 subject to designa-
ted installation
Class A
6110330: -25 °C ... + 55 °C
6110130: -30 °C ... + 60 °C
6220130: -30 °C ... + 55 °C
10 years at +20 °C (without
Bluetooth OBELISK top3)
± 0.25 s/day (25 °C)
4 kV
2
Changeover contact
2600 W
2600 W
2600 VA
2600 VA
1300 VA (130 µF)
1100 W
50 W
600 W
IP 40
–30 °C ... +55 °C
15 m on open air test site
9. Contact
Theben AG
Hohenbergstr. 32
72401 Haigerloch
GERMANY
Phone +49 7474 692-0
Fax +49 7474 692-150
Hotline
Phone +49 7474 692-369
hotline@theben.de
Addresses, telephone numbers etc.
www.theben.de
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr 611 rc top3Tr 622 top3611013061103306220130

Table of Contents