Tap Adjustment - Rangemaster Toledo 90 Dual Fuel User Manual

Installation & service instructions
Hide thumbs Also See for Toledo 90 Dual Fuel:
Table of Contents

Advertisement

WARNING - SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Conversion to LP gas
Servicing - warning
This conversion must be performed by a competent
person. After conversion the installation must comply
with the relevant regulations and also the local electricity
supply company requirements. Read the instructions
before converting this appliance.
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead to
prosecution.
This instruction must be used in conjunction with
the rest of the appliance instruction, in particular
for information on Standards, cooker positioning,
connection hose suitability etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Conversion
Disconnect from electricity and gas before servicing.
Check appliance is safe when you have fi nished.
This appliance is supplied set for G 20 Natural gas at
20millibar. It packed with a conversion kit for LP gas.
Injectors
Remove burner caps and heads. Remove old jets. Fit
the new jets (see Technical Data section at the back of
the book for correct jets). Reassemble in reverse order.

Tap adjustment

Disconnect from electricity supply.
Open the oven door & or grill door and remove the fi xing
screws underneath the control panel. NB some models
have a plate under the facia held in place by the bottom
fi xing screws.
Pull off all the control knobs.
Slide the control panel to the right and then pull forward.
Take care not to damage or strain the wiring.
Lift the control panel, pull forward.
Take care not to damage or strain the wiring.
To convert to other gases.
Turn the bypass screw on each control clockwise to the
stop.
Refi t the control panel.
Stick on label
Stick the LP gas label over the natural gas part of the
appliance data label.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at one of the left
hand hotplate burner jets. Lift off a burner head. Fit the
pressure gauge to the jet. Turn on the hotplate burner
and turn on and light one of the other burners.
The pressure should be 29mbar for Butane and 37mbar
for Propane. After checking the pressure, turn the taps
off and replace the burner head.
Reassemble burner top, making sure it is reassembled
in the correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.
29