Transport

CAUTION!
When transporting the heat pump, ensure that it is not tilted
more than 45° (in any direction).
Transport to the final installation location should be carried out
with a pallet. The basic device can be transported with a lift
truck or a crane.
The transport eyebolts must be removed after crane transport,
and the openings must be closed using the vent plugs supplied.
After transportation, the transport fastening in the device is to
be removed from both sides of the base.
CAUTION!
Before start-up, the transport fastening must be removed.
www.dimplex.de
Remove/screw in
transport lock
(4x)
452167.66.48-EN · FD 0212
5

Installation

5.1 General

The device must be installed on a permanently level, smooth
and horizontal surface. The frame around the device must lie
tightly against the floor to guarantee adequate sound insula-
tion, to prevent water-bearing parts from cooling out and to
protect the inside of the device from small animals. If this is not
the case, additional insulation measures may be necessary. To
prevent small animals from entering the inside of the device, it
may be necessary to seal the connection hole in the base plate,
for example. Furthermore, the heat pump should be set up so
that the air outlet direction of the ventilator is perpendicular to
the main wind direction to allow unrestricted defrosting of the
evaporator. The heat pump is designed for installation on even
ground. If the installation conditions differ (installation on a
platform or flat roof) or there is a greater risk of the heat pump
tipping over (due to an exposed position or high wind expo-
sure), additional protection against tipping over must be pro-
vided. The responsibility for the
heat pump installation lies with the specialist system construc-
tion company. During the installation, local requirements such
as building regulations, static load of the building, and wind ex-
posure must be accounted for.
It must be possible to carry out maintenance work without hin-
drance. This is ensured when observing the distances to solid
walls as shown in the figure.
1,0 m
The specified dimensions are valid for stand-alone installation
only.
NOTE
The heat pump is not intended for use above 2000 metres
(mean sea level).
CAUTION!
Do not restrict or block the area around the air intake or outlet.
CAUTION!
Observe country-specific building regulations!