Dimplex LA 3860 Installation And Operating Instruction

Dimplex LA 3860 Installation And Operating Instruction

Air-to-water heat pump for outdoor installation

Advertisement

Quick Links

LA 3860
Installation and
Operating Instruction
Air-to-Water
Heat Pump for
Outdoor Installation
Order no.: 452167.66.48-EN
Glen
Dimplex
Deutschland
Dimplex
EN · FD 0212

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex LA 3860

  • Page 1 Glen Dimplex Deutschland Dimplex LA 3860 Installation and Operating Instruction Air-to-Water Heat Pump for Outdoor Installation Order no.: 452167.66.48-EN EN · FD 0212...
  • Page 3: Table Of Contents

    LA 3860 English Table of contents Safety notes..............................EN-2 1.1 Symbols and markings ..............................EN-2 1.2 Intended use..................................EN-2 1.3 Legal regulations and directives ..........................EN-2 1.4 Energy-efficient use of the heat pump........................EN-2 Purpose of the heat pump ........................EN-3 2.1 Application ..................................EN-3 2.2 Operating principle................................EN-3 Scope of supply ............................EN-4...
  • Page 4: Safety Notes

    English LA 3860 1.4 Energy-efficient use of the heat Safety notes pump 1.1 Symbols and markings By operating this heat pump, you are helping to protect the en- vironment. A prerequisite for energy-efficient operation is the Particularly important information in these instructions is correct design of the heat source system and heating system.
  • Page 5: Purpose Of The Heat Pump

    LA 3860 English 2.2 Operating principle Purpose of the heat pump Surrounding air is drawn in by the fan and fed through the evap- 2.1 Application orator (heat exchanger). The evaporator cools the air, i.e. it ex- tracts heat from it. This extracted heat is then transferred to the The air-to-water heat pump is to be used exclusively for the working medium (refrigerant) in the evaporator.
  • Page 6: Scope Of Supply

    English LA 3860 Scope of supply 3.1 Basic device The heat pump contains the components listed below. The refrigeration circuit is "hermetically sealed" and contains the fluorinated refrigerant R407C included in the Kyoto proto- col. Information on the GWP value and CO equivalent of the refrigerant can be found in the chapter Device information.
  • Page 7: Transport

    LA 3860 English Transport Installation CAUTION! 5.1 General When transporting the heat pump, ensure that it is not tilted more than 45° (in any direction). The device must be installed on a permanently level, smooth and horizontal surface. The frame around the device must lie...
  • Page 8: Condensate Pipe

    English LA 3860 CAUTION! Assembly For installation close to walls the physical influences of the building must be considered. No windows or doors should be 6.1 General present in the area surrounding the air outlet of the ventilator. The following connections need to be established on the heat...
  • Page 9 LA 3860 English Note: Scale formation in domestic hot water heating systems cannot be avoided, but in systems with flow temperatures below 60 °C, The hot water connections must be established according to the problem can be disregarded. With high-temperature heat the dimensional drawing (see Cap.
  • Page 10: Electrical Connection

    English LA 3860 6.3 Electrical connection Start-up 3 lines/cables must be routed to the heat pump in total: 7.1 General  A standard 5-core cable is used to connect the heat pump to the power supply. To ensure that start-up is performed correctly, it should only be The cable must be provided on-site.
  • Page 11: Procedure

    LA 3860 English 7.3 Procedure 8.2 Cleaning the heating system The heat pump is started up via the heat pump manager. Ad- CAUTION! justments should be made in compliance with the instructions. The installed dirt traps must be cleaned at regular intervals.
  • Page 12: Cleaning The Air System

    English LA 3860 8.3 Cleaning the air system Faults / troubleshooting The evaporator, ventilator and condensate outflow should be This heat pump is a quality product and is designed for trouble- cleaned of contamination (leaves, twigs, etc.) before each new free operation.
  • Page 13: Device Information

    LA 3860 English 11 Device information Type and order code LA 3860 Design Heat source Version Universal Controller WPM wall-mounted Thermal energy metering Integrated Installation location Outside Performance level Operating limits Heating water flow / return °C to 60 -2(to 62 -2)
  • Page 14 English LA 3860 Additional model features Type of defrosting (according to need) Reverse circulation Condensate tray frost protection / Water in device Heated / Yes protected against freezing max. operating overpressure (heat source / heat sink) 10 Performance / coefficient of performance (COP) 10.1 SCOP (Seasonal coefficient of performance) average climate 35 °C / 55 °C...
  • Page 15: Product Information As Per Regulation (Eu) No 813/2013, Annex Ii, Table 2

    Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 16: Dimension Drawings

    English LA 3860 13 Dimension Drawings 13.1 Dmension Drawing EN-14 452167.66.48-EN · FD 0212<Betonung> www.dimplex.de...
  • Page 17: Diagrams

    LA 3860 English 14 Diagrams 14.1 Characteristic curves for heating operation Heizleistung in [kW] Wasseraustrittstemperatur in [°C] Heating capacity in [kW] Water outlet temperature in [°C] Puissance de chauffage en [kW] Température de sortie de l'eau en [°C] EN 14511 A7 W35...30...
  • Page 18: Operating Limits Diagram Heating

    English LA 3860 14.2 Operating limits diagram heating 6,0 m³/h 3,4 m³/h Wasseraustritt (+0 / -2 K) Water outlet (+0 / -2 K) Sortie d'eau (+0 / -2 K) *Wassereintritt *Water inlet *Entrée d'eau Die maximalen Vorlauftemperaturen werden beim geforderten Mindestheizwasserdurchfluss erreicht.
  • Page 19: Integration Diagram

    LA 3860 English 15 Integration diagram 15.1 Hydraulic integration diagrams www.dimplex.de 452167.66.48-EN · FD 0212<Betonung> EN-17...
  • Page 20: Legend

    English LA 3860 15.2 Legend Shut-off valve Safety valve combination Circulating pump Expansion vessel Room temperature-controlled valve Shut-off valve with check valve Shutoff valve with drainage Heat consumer Four-way reversing valve Temperature sensor Flexible connection hose Check valve Three-way mixer...
  • Page 21: Declaration Of Conformity

    LA 3860 English 16 Declaration of Conformity You can find and download the current CE conformity declaration at: https://dimplex.de/la3860 www.dimplex.de 452167.66.48-EN · FD 0212<Betonung> EN-19...
  • Page 22 English LA 3860 EN-20 452167.66.48-EN · FD 0212<Betonung> www.dimplex.de...
  • Page 23 LA 3860 English www.dimplex.de 452167.66.48-EN · FD 0212<Betonung> EN-21...
  • Page 24 Glen Dimplex Deutschland On site service Head office After-sales service, technical support and Glen Dimplex Deutschland GmbH spare partsl. Assistance before and Am Goldenen Feld 18 after installation of your equipment D-95326 Kulmbach T +49 9221 709-545 T +49 9221 709-101...