Dimplex LA 60S-TU Installation And Operating Instruction

Dimplex LA 60S-TU Installation And Operating Instruction

Air-to-waterheat pump for outdoor installation

Advertisement

Quick Links

LA 60S-TU
Installation and
Operating Instruction
Air-to-Water
Heat Pump for
Outdoor Installation
Order no.: 452163.66.89-EN
Glen
Dimplex
Deutschland
Dimplex
EN · FD 0103

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex LA 60S-TU

  • Page 1 Glen Dimplex Deutschland Dimplex LA 60S-TU Installation and Operating Instruction Air-to-Water Heat Pump for Outdoor Installation Order no.: 452163.66.89-EN EN · FD 0103...
  • Page 3: Table Of Contents

    LA 60S-TU English Table of contents Safety notes..............................EN-2 1.1 Symbols and markings ..............................EN-2 1.2 Intended use..................................EN-2 1.3 Legal regulations and directives ..........................EN-2 1.4 Energy-efficient use of the heat pump........................EN-2 Purpose of the heat pump ........................EN-3 2.1 Application ..................................EN-3 2.2 Operating principle................................EN-3 Scope of supply ............................EN-4...
  • Page 4: Safety Notes

    English LA 60S-TU 1.4 Energy-efficient use of the heat Safety notes pump 1.1 Symbols and markings By operating this heat pump, you are helping to protect the en- vironment. A prerequisite for energy-efficient operation is the Particularly important information in these instructions is correct design of the heat source system and heating system.
  • Page 5: Purpose Of The Heat Pump

    LA 60S-TU English 2.2 Operating principle Purpose of the heat pump Surrounding air is drawn in by the fan and fed through the evap- 2.1 Application orator (heat exchanger). The evaporator cools the air, i.e. it ex- tracts heat from it. This extracted heat is then transferred to the The air-to-water heat pump is to be used exclusively for the working medium (refrigerant) in the evaporator.
  • Page 6: Scope Of Supply

    English LA 60S-TU Scope of supply 3.1 Basic device The heat pump contains the components listed below. The refrigeration circuit is "hermetically sealed" and contains the fluorinated refrigerant R407C included in the Kyoto proto- col. Information on the GWP value and CO equivalent of the refrigerant can be found in the chapter Device information.
  • Page 7: Transport

    LA 60S-TU English Transport Installation CAUTION! 5.1 General When transporting the heat pump, ensure that it is not tilted more than 45° (in any direction). The device must be installed on a permanently level, smooth and horizontal surface. The frame around the device must lie...
  • Page 8: Condensate Pipe

    English LA 60S-TU 6.2 Connection on heating side CAUTION! In cases of installation close to a wall, there may be more The heating system connections on the heat pump are to be sediment in the air inlet and outlet areas due to the air current.
  • Page 9: Electrical Connection

    LA 60S-TU English 6.3 Electrical connection Note: The hot water connections must be established according to 3 lines/cables must be routed to the heat pump in total: the dimensional drawing (see Cap. 1.1 on page II) in the coun- ...
  • Page 10: Start-Up

    English LA 60S-TU Start-up Cleaning / maintenance 7.1 General 8.1 Maintenance To ensure that start-up is performed correctly, it should only be To protect the paintwork, avoid leaning anything against the carried out by an after-sales service technician authorised by device or putting objects on the device.
  • Page 11: Cleaning The Air System

    LA 60S-TU English Residue from lubricants and sealants may also contaminate the The upper panels are hooked into the cover panel. Loosen the heating water. two screws for dismantling and unhook the panels by pulling In the case of severe contamination leading to a reduction in them back.
  • Page 12: Device Information

    English LA 60S-TU 11 Device information Type and order code LA 60S-TU Design Heat source Version Universal Controller WPM wall-mounted Thermal energy metering Integrated Installation location Outside Performance level Operating limits Heating water flow / return °C to 60 -2(to 62 -2)
  • Page 13 LA 60S-TU English Additional model features Type of defrosting (according to need) Reverse circulation Condensate tray frost protection / Water in device Heated / Yes protected against freezing max. operating overpressure (heat source / heat sink) Performance / coefficient of performance (COP) SCOP (Seasonal coefficient of performance) average climate 35 °C / 55 °C...
  • Page 14: Product Information As Per Regulation (Eu) No 813/2013, Annex Ii, Table 2

    Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 15: Dimension Drawings

    LA 60S-TU English 13 Dimension Drawings 13.1 Dmension Drawing www.glendimplex.de 452163.66.89-EN · FD 0103 EN-13...
  • Page 16: Diagrams

    English LA 60S-TU 14 Diagrams 14.1 Characteristic curves for heating operation Heizleistung in [kW] Wasseraustrittstemperatur in [°C] Heating capacity in [kW] Water outlet temperature in [°C] Puissance de chauffage en [kW] Température de sortie de l'eau en [°C] EN 14511 A7 W35...30...
  • Page 17: Operating Limits Diagram Heating

    LA 60S-TU English 14.2 Operating limits diagram heating 6,0 m³/h 3,4 m³/h Wasseraustritt (+0 / -2 K) Water outlet (+0 / -2 K) Sortie d'eau (+0 / -2 K) *Wassereintritt *Water inlet *Entrée d'eau Die maximalen Vorlauftemperaturen werden beim geforderten Mindestheizwasserdurchfluss erreicht.
  • Page 18: Integration Diagram

    English LA 60S-TU 15 Integration diagram 15.1 Hydraulic integration diagrams EN-16 452163.66.89-EN · FD 0103 www.glendimplex.de...
  • Page 19: Legend

    LA 60S-TU English 15.2 Legend Shut-off valve Safety valve combination Circulating pump Expansion vessel Room temperature-controlled valve Shut-off valve with check valve Shutoff valve with drainage Heat consumer Four-way reversing valve Temperature sensor Flexible connection hose Check valve Three-way mixer...
  • Page 20 Glen Dimplex Deutschland Service and technical support Head office After-sales service, technical support Glen Dimplex Deutschland GmbH and spare parts Am Goldenen Feld 18 Assistance before and after installation D-95326 Kulmbach of your equipment T +49 9221 709-100 T +49 9221 709-545...