Chamberlain ELITE EL2000LG Programming Manual page 7

Table of Contents

Advertisement

Qui ck R ef eren ce
Programming
Page
Number
57
34
Delete an Entry Code
58
37
Assign Utility Option
59
37
Assign Special Use
Entry Code
60
24
Assign Each External
Access Control
Device a "Door Number"
61
24
Assign "Each" Door
Number to One or
More Relays
63
51
Assign Door Use Time Zone
64
53
Set Anti-Passback Entry/Exit
for Specific Devices
65
23
Set Each "Relay Mode"
to get the
Appropriate Response
66
23
Set Each Relay's
"Activation Time"
67
65
Request to Exit Device (REX)
68
66
Door Sensing Devices
69
64
Postal Lock Switch
70
64
Autocall Device
71
43
Set the Default Card Type
73
43
Set the Default Facility Code
74
43
Enable or Disable Ignore
Facility Code when
a Card is Used
75
36
Change Entry Code
Door Access
78
40
Change Card Code
Door Access
80
40
Add a Basic Card
Factory
Description of Task
Setting
Main keypad
assigned door1
Device 1=door 1
Device 2=door 2
Device 3=door 3
Device 4=door 4
D1=Relay 1
D2=Relay 2
D3=Relay 3
D4=Relay 4
Enabled
Disabled
All Relays=
"1-Strike"
All Relays=
10 seconds
R1=Door 1
R2=Door 2
R3=Door 3
R4=Door 4
DS1= Door 1
DS2= Door 2
DS3= Door 3
DS4= Door 4
Door 1
Enabled
All Doors
All Doors
Page 6
Programming
Procedure
57 # (entry code) #
Off
58 # (entry code) # (Option; 0=Off, 1=Daily,
2=Weekly, 3=Never) # (number of uses 1-15)
59 # (entry code) # enable/disable #
60 # (device 1-4) # (door 1-4) #
61 # (door 1-4) # (relays to activate
0000-1111) # Order of relay is: relay 4-relay
-3 -relay 2-relay 1 for an example if you
want relay 4 active you would enter
1000, if you want relay 1 active you would
enter 0001
63 # (door 1-4) # (time zone, 0-63) #
64 # (device 0-4) #
(0-3; 0=disable, 1=set device to timed
anti-passback, 2=set device to true
anti-passback-entrance, 3=set device for true
anti-passback-exit) #
65 # (relay 1-4) # (1-5; 1=strike, 2=shunt,
3=CCTV, 4=alarm, 5=control) #
66 # (relay 1-4) # time (1-300 seconds)
67 # (REX number 1-4) # (select REX option:
0=disabled, 1=use your door settings or 2=use
specific relay(s) 0000-1111) #
Order of Relays are 4321
68 # (sensor number 1-4) # (select sensor
option: 0=disabled, 1=use your door settings or
2=use specific relay(s) 0000-1111) #
Order of Relays are 4321
69 # (door 0-4; 0=no postal lock) #
0000
70 # (relays to activate 0000-1111) #
Order of relays are 4321 (Factory Default: 0000)
30
71 # (26 or 30) # (Factory Default: 30)
0
73 # (0-255) #
74 # (0=disable; 1=ignore) #
75 # (entry code) # (door 0=any door,
1=door 1, 2=door 2, 3=door 3, 4=door 4) #
78 # (card code) # (facility code) # (card type,
26 or 30) # (door 0=any door, 1=door 1,
2=door 2, 3=door 3, 4=door 4) #
80 (card PIN code) # (facility code) # (card
type, 26 or 30) #

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite el seriesElite el2000lbElite el2000ss

Table of Contents