TECHNICAL SPECIFICATIONS

Technology:
Detection mode:
Detection width:
Mounting Height:
Remission factor:
Angular resolution:
Testbody:
Emission characteristics:
IR laser:
Supply Voltage:
Power Consumption:
Response time:
Output:
Rating:
Test:
Rating:
Temperature Range:
Degree of Protection:
Humidity:
Vibrations:
Material:
Norm Conformity:
Mounting angle (rotational):
Tilt angle:
Pollution on front screens:
For version compatibiltiy serial number information, please see Application Note 76.0017 or contact BEA for technical support.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA,
Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/
device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer's recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294,
UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
Page 2 of 16
laser, time-of-flight measurement
presence
20 – 48"
(measured from leading edge to sensor LED)
75 – 98"
(measured from finished floor to sensor LED)
> 2%
2.56°
28" (H) x 12" (W) x 8" (D)
wavelength 905 nm; max. output pulse power 35 W (CLASS 1)
12 – 30 VDC (15 W Class II)
< 15 W
typ. 40 ms (max. 80 ms)
4 electro-mechanic relays (galvanic isolated - polarity free)
All outputs Class 2 supply, 12 – 24 VAC / 12 – 30 VDC, max. 15 W
2 optocouplers (galvanic isolated – polarity-free)
12 – 30 VDC, max. 15 W
-13 – 121 °F (-25 – 55 °C)
Hub: IP20/NEMA 1
Sensor: IP53/NEMA 3
0 – 95% non-condensing
< 2 G
PC/ASA
EN 60825-1-Eye-safety class 1 IR laser (905 nm)
UL10B/C fire-rated 3 hours (file #R39071)
35° fixed
0 – 5° (for angles less than 5°, contact Tech Support)
max. 30%; homogenous
Specifications are subject to change without prior notice.
All values have been measured in specific conditions.
75.5753.21 LZR-MICROSCAN T 20210628