BEA ULTIMO Manual

BEA ULTIMO Manual

Activation and safety sensor for automatic, sliding doors

Advertisement

Visit website for
available languages
of this document.
75.0034.03 ULTIMO 20220120
ULTIMO
ACTIVATION AND SAFETY SENSOR FOR
AUTOMATIC, SLIDING DOORS
Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for BEA ULTIMO

  • Page 1 ULTIMO ACTIVATION AND SAFETY SENSOR FOR Visit website for available languages AUTOMATIC, SLIDING DOORS of this document. 75.0034.03 ULTIMO 20220120 Page 1 of 20...
  • Page 2 DESCRIPTION cover light pipe radar antenna AIR receiver AIR emitter [for internal use only] AIR curtain angle adjustment knob 10. main adjustment knob 11. main connector 12. [for future development] Page 2 of 20 75.0034.03 ULTIMO 20220120...
  • Page 3: Technical Specifications

    Cable length/gauge 10' / 26 AWG Degree of protection IP54 Compliance R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU Specifications are subject to change without prior notice. All values measured in specific conditions. 75.0034.03 ULTIMO 20220120 Page 3 of 20...
  • Page 4: Led Signals

    (according to ANSI 156.10) made or attempted by the sensor. before leaving the premises. unauthorized personnel. Page 4 of 20 75.0034.03 ULTIMO 20220120...
  • Page 5: Mounting And Wiring

    • Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness and/or sensor. 75.0034.03 ULTIMO 20220120 Page 5 of 20...
  • Page 6 Sensor monitoring logic is defaulted to ActiveLow. ActiveHigh monitoring logic is selectable via InTestLogic on menu 3. To turn sensor monitoring OFF, navigate to menu 3 on the LCD and set InTestMode to OFF. Page 6 of 20 75.0034.03 ULTIMO 20220120...
  • Page 7 - Radar menu - Outputs & Diagnostics menu VALUE CHECK WITH REMOTE CONTROL Pressing a parameter symbol on your remote control displays the saved value directly on the LCD screen. Do not unlock first. 75.0034.03 ULTIMO 20220120 Page 7 of 20...
  • Page 8: How To Use The Remote Control

    AIR Presence Time will result in 2 green LED blinks. RESTORING TO FACTORY VALUES partial reset full reset full reset = restores to factory defaults partial reset = restores all settings except monitoring and outputs Page 8 of 20 75.0034.03 ULTIMO 20220120...
  • Page 9 ) to select Narrow shape. To check the existing radar field size/shape, use the following sequence: 1x = narrow 2x = wide x = number of flashes = corresponds to the field size 75.0034.03 ULTIMO 20220120 Page 9 of 20...
  • Page 10 (settings 1 and 4) NON-THRESHOLD SETTINGS a solid line indicates that the given curtain is always active (settings 3, 6, and 7) Page 10 of 20 75.0034.03 ULTIMO 20220120...
  • Page 11 First, turn on the red spots, and then verify that either C1 is at least in line with the moving door panel (see image below, left) or *preferred* through the door opening (see image below, right). Next, ensure that C2 is within 3 inches of face of door. PREFERRED 75.0034.03 ULTIMO 20220120 Page 11 of 20...
  • Page 12 2. Always verify the actual AIR detection field by walk-testing according to ANSI 156.10. Do not use a SPOTFINDER to verify the AIR detection field. Additional adjustments are possible by LCD or remote control (see OVERVIEW OF SETTINGS). Page 12 of 20 75.0034.03 ULTIMO 20220120...
  • Page 13 The LED will flash white, confirming the synchronization is detected. If an overlapping safety field is found in the threshold of the door, ULTIMO will remain synchronized for 2 minutes while the door is closed. If activation does not occur for 2 minutes, the white LED will flash, confirming synchronization is lost.
  • Page 14: Push Button

    During setup, the LCD will display the camera icon and the LED will slowly flash red/green and then turn off. slow flash Test the proper operation of the system installation before leaving the premises! Page 14 of 20 75.0034.03 ULTIMO 20220120...
  • Page 15 75.0034.03 ULTIMO 20220120 Page 15 of 20...
  • Page 16 Page 16 of 20 75.0034.03 ULTIMO 20220120...
  • Page 17 75.0034.03 ULTIMO 20220120 Page 17 of 20...
  • Page 18: Troubleshooting

    Increase tilt angle of the interfering curtain Error and/or C3 interfering with door to move the curtain away from the threshold during opening cycle (see pages 9 – 10). troubleshooting continues on the next page Page 18 of 20 75.0034.03 ULTIMO 20220120...
  • Page 19: Orange Led

    Check position of cable and sensor cover. The sensor sees the door Remove the objects if possible. or other unwanted moving objects. Change radar field size, angle, or immunity. troubleshooting continues on the next page 75.0034.03 ULTIMO 20220120 Page 19 of 20...
  • Page 20 BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.