TECHNICAL SPECIFICATIONS

Technology:
Detection mode:
Detection range:
Remission factor:
Angular resolution:
Min. detected object size (typ.):
Emission characteristics:
IR laser:
Visible laser:
Supply voltage:
Power consumption:
Peak current at power-on:
Cable length:
Response time:
Output:
Max. switching voltage:
Max. switching current:
Switching time:
Output resistance:
Voltage drop on output:
Leakage current:
Input:
Max. contact voltage:
Voltage threshold:
Response time monitoring input:
LED-signal:
Dimensions:
Weight:
Material:
Colour:
Mounting angles on bracket:
Rotation angles on bracket:
Tilt angles on bracket:
Protection degree:
Temperature range:
Humidity:
Vibrations:
Pollution on front screens:
Conformity:
laser scanner, time-of-flight measurement
motion and presence
5 m x 5 m @ 2% remission factor
> 2 %
0,3516 °
2,1 cm @ 3 m ; 3,5 cm @ 5 m (in proportion to object distance)
wavelength 905 nm; output power 0.10 mW (CLASS 1)
wavelength 635 nm; output power 0.95 mW (CLASS 2)
10-35 V DC @ sensor side*
< 5 W
1.8 A (max. 80 ms @ 35 V)
2 m
typ 20 ms; max. 80 ms
2 electronic relays (galvanic isolated - polarity free)
35 V DC / 24 V AC
80 mA (resistive)
t
=5 ms; t
=5 ms
ON
OFF
typ 30 Ω
< 0.7 V @ 20 mA
< 10 µA
2 optocouplers (galvanic isolated - polarity free)
30 V DC (over-voltage protected)
Log. H: >8 V DC; Log. L: <3 V DC
< 5 ms
1 blue LED: power-on status
1 orange LED: error status
2 bi-coloured LEDs: detection/output status
125 mm (D) x 93 mm (W) x 70 mm (H) (mounting bracket + 14 mm)
310 g (mounting bracket: + 60 g)
PC/ASA
black
-45 °, 0 °, 45 °
-5 ° to +5 ° (lockable)
-3 ° to +3 °
IP65
-30 °C to +60 °C if powered; -10 °C to +60 °C unpowered
0-95 % non-condensing
< 2 G
max. 30 %; homogenous
2014/35/EU: LVD; 2011/65/EU: RoHS 2; 2014/30/EU: EMC;
EN 50155; EN 60529; IEC 60825-1; EN 60950-1;
EN 61000-6-2; EN 61000-6-3;
IEC 61496-1; EN 61496-3 ESPE Type 2;
EN 62061 SIL 2
Specifications are subject to changes without prior notice.
All values measured in specific conditions.
* The Equipment must be powered by an approved Class II SELV limited power source.
This requirement consists of the need for double insulation between primary voltages and the
Equipment supply
(green: no detection; red: detection)
11

Advertisement

Table of Contents
loading

Table of Contents