CRYSTAL INFRARED PRESENCE CURTAIN
The Crystal active infrared presence curtain is ideal for threshold safety as well as an activation device when cross
traffic is a concern. It is universally compatible with any door control and easily installed on new doors as well as on
existing doors for retrofit purposes. The Crystal's technology utilizes the process of multiplexing, which assures that
it is constantly scanning the background looking for any changes. Finally if the change in background remains
constant for a set time (adjustable 1 minute or 10 minutes) the sensor learns it and allows your door to return to
normal operation.
For openings narrower than 8' and lower than 13'
4" D

TECHNICAL SPECIFICATIONS

Installation Height:
Detection Zone:
Mounting Angle:
Power Supply:
Energy Consumption:
Output - Contact Ratings:
Max. voltage
Max. current
Max. switching power
Frequency:
Response Time:
Relay hold time:
Auto Learn Time
Temperature range:
Dimensions:
Weight:
Material:
Length of Cable:
75.1033 V1 Feb 2001
Crystal
6' W
For openings greater than 8' feet and higher than 13'
(See page 4 on how to pulse the frequency when 2 Crystals
are mounted next to one another.)
Crystal
7' to 13' for Industrial Doors
Wide pattern: 6'
Narrow pattern: 3'
Depth: 4"
From 3° to 21°
12 to 30 V DC ± 10%
12 to 24 V AC ± 10%
< 1 W (VA)
Dry Contacts
60 V DC / 125 V AC
1 A (resistive)
30 W (DC) / 60 VA (AC)
50 to 60 Hz
< 50ms
1.5 seconds (fixed)
1 or 10 minutes
-30° to +131° F
10" L x 2" H x 1.5" D
7 oz.
Black ABS and Polycarbonate
6' of 4 conductor cable with JST Connector
30' cable assembly available upon request for $10