Technical Specifications - BEA IXIO-DP1 User Manual

Opening & safety sensor for automatic sliding doors
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS

Supply voltage:
12 V - 30 V DC +/-10%
Power consumption:
< 2.5 W
Mounting height:
2 m to 3.5 m
Temperature range:
-25°C to +55°C; 0-95% relative humidity, non condensing
Degree of protection:
IP54
Noise:
< 70 dB
Expected lifetime:
20 years
Applicable directives:
RED 2014/53/EU; MD 2006/42/EC; ROHS 2 2011/65/EU
Detection mode:
Technology:
Output:
Norm conformity:
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA-SENSORS.COM
BEA hereby declares that the IXIO-DP1 is in conformity with the basic requirements and the other relevant provisions of the directives
2014/53/EU, and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089612
Angleur, September 2017
The complete declaration of conformity is available on our website
Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
(to be operated from SELV compatible power supplies only)
(according to the applicable laws and regulations)
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Pierre Gardier, authorized representative and responsible for technical documentation
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
2
-Input:
Pulse polarity: positive or negative (adjustable)
Impedance:
- Positive pulse: 2 K to ground
- Negative pulse: 470 R to + sensor power supply
Pulse voltage: 6 V to 30 V
Pulse duration: 4 µs to 500 µs
Duty cycle: max. 50%
-Output:
Pulse polarity: negative
Level:
- Standby: Pulse from V to ground
- Detection: V Supply
Topology: op-collector with 4.7 K to 3.3 V
Max. sink current: 25 mA with external 1 K to 24 V
EN 12978
EN ISO 13849-1 PL «c» CAT. 2
(under the condition that the door control system
monitors the sensor at least once per door cycle)
IEC 61496-1 ESPE Type 2
EN 16005 Chapter 4.6.8;
DIN 18650-1 Chapter 5.7.4
BS 7036-1 Chapter 8.1
Specifications are subject to changes without prior notice.
All values measured in specific conditions and with a temperature of 25°C.

Advertisement