Service Connections

Service Connections
– FIELD WIRE ELECTRICAL CONNECTION: Field wiring electrical connection to be as specified on data plate.
– SINK DRAIN: 2" (51 mm) IPS piped to open floor drain. No Solid Connection.
– CONDENSATE COLD WATER: 1/2" (13 mm) NPT at 25-50 PSI (170-345 kPa). (OPTIONAL)
– BOILER FEED WATER: 1/2" (13 mm) NPT at 25-50 PSI (170-345 kPa).
– FAUCET COLD WATER: 3/8" (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61 compliant.
FC
– FAUCET HOT WATER: 3/8" (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61 compliant.
FH
– STEAM TAKE-OFF CONNECTION: 3/4" (19 mm) IPS optional to operate adjacent equipment.
Model
Capacity
a
EMT-6
6 gal. (23 L)
12 (305) 14.5 (368) 66.13 (1680)
EMT-10
10 gal. (38 L) 16 (406)
EMT-12
12 gal. (45 L) 16 (406)
Model
EMT-6
EMT-10
EMT-12
Water is the essential ingredient in steam equipment, water quality is the major factor affecting the performance of your appliance. Crown Steam Group offers a
Comprehensive Water Treatment System which exceeds our minimum water requirements. Proof of installation and proper cartridges replacement is required for
warranty coverage. Water supply to Crown Steam Group steamers must be within these guidelines.
Total dissolved solids.......................Less than 60 PPM
Total alkalinity ........................................ Less than 20 PPM
Silica ....................................................... Less than 13 PPM
Water which does not meet these standards should be treated with the installation of Middleby's Water Treatment System. Call 919-762-1000 if you have questions
concerning your water meeting these parameters.
*Failure or malfunction of this appliance due to poor water quality is not covered under warranty.
Reference www.crownsteamgroup.com for complete warranty details and instructions.
Terry System Cartridge Changes / Installation – "2-3 gallons of water MUST be purged at each cartridge change or new installation prior to
water supply being fed to the steamer. Failure to do so can result in component damage within the steamer which is not covered under warranty.
For additional guidance on proper installation, refer to install documentation provided with each Terry System and Replacement Cartridge Set."
As continued product improvement is a policy of Crown, specifications are subject to change without notice.
4
PAGE
OF 20
Direct Steam Kettles Mounted on Electric Boiler Cabinet Base
NOTE: SPLASH GUARD NOT SHOWN IN FRONT VIEW.
SERVICE CONNECTIONS
DIMENSIONS AND SPECIFICATIONS
b
c
d
3.5
15 (381)
65.13 (1654)
(89)
(267)
17 (432)
67.13 (1705)
ELECTRICAL CHARACTERISTICS
Phase
kW
208V
3
24
66.6
3
36
99.9
3
42
116.6
3
48
N/A
WATER QUALITY STATEMENT
INSTALLATION & OPERATION MANUAL 10071 REV 4 (07/22)
e
f
g
h
j
10.5
8.75
5.5
7
2.5
11.12
(222)
(140)
(178)
(64)
(283)
Amps Per Line
220V
240V
380V
63
57.7
36.5
94.5
86.6
54.7
110.2
101
63.8
N/A
115.5
72.9
Chlorine ............................Less than 1.5 PPM
pH Factor .........................6.8 - 7.3
DISCLAIMER
k
l
m
Shipping Weight
450 lbs. [204 kg.]
9
12
470 lbs. [213 kg.]
(229)
(305)
479 lbs. [217 kg.]
415V
480V
33.4
28.9
50.1
43.3
58.4
50.5
66.8
57.7
Min. Clearance
SIDES 0 [0 mm]
BACK 0 [0 mm]