Chapter 8 Specifications

8.4 NCG-1950 Operation Panel Unit

Performance
a)
Mounting
b)
Interface to the RCU
1)
Standard
2)
Protocol
3)
Power supply
c)
Indication
d)
Operation
e)
USB connector
f)
Compass safety distance
1)
Standard
2)
Steering
Environmental condition
a)
Operating temperature
b)
Temperature and humidity
c)
Vibration
d)
Protection class
General specification
a)
Power voltage
b)
Size
c)
Mass
d)
Color
126
Flush mount type
IEEE802.3 (10Base-T/100Base-TX)
TCP/IP
Supply from the RCU
7-inch wide color LCD (800 x 480 pixels)
Speaker
Touch panel
Rotary knob
A type receptacle (for USB memory)
0.5m
0.3m
-15°C to +55°C (IEC60945 protected type)
+40°C, 93% (without dew condensation)
2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
IP22
DC +24V ±5%
225(w) x 37.5(d) x 136(h) mm (without projection)
0.8kg
N2.5 semi-gloss