Performance (continued)
k)
External alarm lamp output
1)
Interface
2)
Operation
3)
Current
l)
GPS select signal input
1)
Interface
2)
Operation
m) Compass safety distance
1)
Standard
2)
Steering
Environmental condition
a)
Operating temperature
b)
Temperature and humidity
c)
Vibration
d)
Protection class
General specification
a)
Power voltage
b)
Power consumption
(Including the fixed protective
capsule unit, and the float-free
capsule unit, the operation panel
unit, and microphone)
c)
Size
d)
Mass
e)
Color
Dry contact
System down (Normal Close / Normal Open)
1A or less at DC +24V
0.5A or less at AC 125V
Dry contact (also serve for external contact input)
Recording GPS selection (Active Open / Active
Close)
0.9m
0.5m
-15°C to +55°C (IEC60945 protected type)
+40°C, 93% (without dew condensation)
2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
IP22
AC 100 to 120V ±10%, 1-phase 50/60Hz (IEC60945)
AC 200 to 240V ±10%, 1-phase 50/60Hz (IEC60945)
230W (In UPS battery charge)
70W (In normal operation)
419.5(w) x 214.0(d) x 480.5(h) mm
22.5kg