Attention Point At Mounting The Capsule - JRC JCY-1950 Instruction Manual

Simplified voyage data recorder
Hide thumbs Also See for JCY-1950:
Table of Contents

Advertisement

Chapter 5 About Float-free Capsule

5.5 Attention point at mounting the capsule

When remove the capsule in order to perform NORMAL SELF-TEST, EXTENDED SELF-TEST
including GNSS (or GPS) test for periodic maintenance or due to occurring communication error,
return the capsule into the bracket after wiping the silicone grease and applying a thin layer of the
attached silicone grease.
If the silicone grease is not applied, please note that it may cause a communication error.
Applying of silicone grease
When return the capsule into the bracket, confirm that capsule is mounted without no gap
between the capsule and the following 2 places (Hunger part and Docking module part).
If there is gap, please re-mount the capsule so that there is no gap.
If there is gap, please note that it may cause a communication error.
NG
OK
Hunger part
NG
OK
Docking Module part
100