Installation; Indoor Unit; Outdoor Unit - Dimplex LIA 0608HXCF M Installation And Operating Instruction

Split air-to-water heat pump with hydrobox
Table of Contents

Advertisement

LIA 0608HXCF M - LIA 1316HXCF M
5

Installation

5.1 Indoor unit

5.1.1 General
The unit should always be installed indoors on a level, smooth
wall. Maintenance work can be carried out easily from the oper-
ator side (a larger minimum distance at the side is required; as-
sembly clearance of 5 cm must be adhered to). This can be en-
sured by maintaining a distance of approx. 1 m at the
front. The indoor unit should be mounted at a height of approx.
1.20 m. Installation must be carried out in a frost-proof room
and using short pipelines.
NOTE
Setup and installation must be performed by an authorised
specialist company.
CAUTION!
The unit must not be mounted or operated near a naked
flame, gas-powered devices, electric heaters or any other
comparable source of ignition.
CAUTION!
The unit must not be installed in a room that is also used as a
workplace or workshop (risk of ignition due to flying sparks).
CAUTION!
When installing the unit, make sure that no ventilation
openings are blocked.
NOTE
The heat pump is not intended for use above 2000 metres
(mean sea level).
www.dimplex.de

5.2 Outdoor unit

It is advisable to install the outdoor unit close to a wall, on a
foundation separate from the building with a minimum
clearance of 0.3 m on the intake side (Fig. 5.1 + Fig. 5.2).
If a canopy is mounted to protect from direct sunlight, rain
or snow it must not impede the heat exchange of the unit.
In the case of a free-standing installation, the foundation is
to be connected on the intake side, flush with the unit. This
will prevent snow from building up between the foundation
and the evaporator.
The minimum clearances (Fig. 5.1) indicated must be ad-
hered to.
When selecting an installation location, it should be en-
sured where possible that persons are not going to be in-
convenienced by the circulation of warm/cold air or by
noise emissions.
The condensate tray offers various options for condensate
draining. In warmer regions, the condensate can drain from
the device freely. In regions with longer periods of frost,
controlled condensate draining is required.
Frost line
Abb. 5.1
Frost line
Abb. 5.2
452172.66.05-EN · FD 0306
Heat pump
0,3 m
Condensate drain
Heat pump
0,3 m
English
Condensate drain
> 5%
EN-7