Circuit Diagrams; Circuit Diagram Lia 0608Hxcf M / Lia 0911Hxcf M - Dimplex LIA 0608HXCF M Installation And Operating Instruction

Split air-to-water heat pump with hydrobox
Table of Contents

Advertisement

English

18 Circuit diagrams

18.1 Circuit diagram
LIA 0608HXCF M /
LIA 0911HXCF M
FACTORY
SETTINGS
brown
brown
EN-50
Fan
brown
blue
PCB B, Main control board
for 1-ph
To heater band
of drain
(>200mA)
452172.66.05-EN · FD 0306
blue
black
red
To internal device
communication
Note: please use
a 2-core
shielded cable
LIA 0608HXCF M - LIA 1316HXCF M
PCB A, Inverter board
for 1-phase
blue
brown
power supply
The leakage circuit breaker
must be installed on
the power supply of the device.
www.dimplex.de

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lia 0911hxcf mLia 1316hxcfLia 1316hxcf m

Table of Contents