Assembly Indoor Unit; General; Opening Indoor Unit; Indoor Unit Fixing - Dimplex LIA 0608HXCF M Installation And Operating Instruction

Split air-to-water heat pump with hydrobox
Table of Contents

Advertisement

English
6

Assembly indoor unit

6.1 General

The following connections need to be established on the indoor
unit (see "Dimension drawing indoor unit" on page 47.)
Flow / return of the heating system
Safety valve outflow
Power supply
Voltage supply
Split refrigerant pipe
Condensate drain
Expansion vessel connection (optional)
NOTE
Setup and installation must be performed by an authorised
specialist company.

6.2 Opening indoor unit

The cover must be removed to allow access to the inside of the
device.
CAUTION!
Before opening the device, ensure that all electric circuits are
disconnected from the power supply.
The two screws on the bottom must be loosened for this. Then
swing out the bottom cover to the front and remove upwards.
3.
3.
1.
NOTE
When removing the unit cover, it must be taken into account
that the length of the connecting cables between the control
panel in the unit cover and the controller on the contact plate
as well as the earthing cable is only 1.5 m. If the device cover
can only be placed further away than this when it has been
removed, the plug connection on the controller or on the
control panel must first be disconnected.
EN-12
2.
1.
452172.66.05-EN · FD 0306
LIA 0608HXCF M - LIA 1316HXCF M
After removing the cover, the electronics area is freely accessi-
ble.
The contact plate contains the power supply connection termi-
nals, heating contactors and the heat pump manager.
CAUTION!
Before switching the electric circuits back on, ensure that the
device has been sealed and live parts cannot be touched.

6.3 Indoor unit fixing

The indoor unit is attached to the wall with the screws and dow-
els (8 mm) included in the scope of supply. The following proce-
dure should be used:
Mount the dowels for the top fastening eyelets.
Screw the screw into the dowel so that the indoor unit can
be mounted.
Mount the indoor unit by the upper fastening eyelets.
Mark the position of the bottom drill holes. Unhook the in-
door unit again
Mount the dowels for the bottom drill holes.
Remount the indoor unit at the top and tighten the screws.
380
400
www.dimplex.de

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lia 0911hxcf mLia 1316hxcfLia 1316hxcf m

Table of Contents