LIA 0608HXCF M - LIA 1316HXCF M

18.4 Legend

PCB A, inverter board for 1-phase
Connection for fan
CN19
Output connection for +12V/9V
CN20
Connection for communication with PCB B
CN32
CN501
Input connection L for the rectifier bridge
ACL
CN502
Input connection N for the rectifier bridge
ACN
Compressor U connection
U
Compressor W connection
W
Compressor V connection
V
PCB B, main control board for 1-phase
Connection for intake temperature sensor
CN1
Communication connection (reserved)
CN2
Reserve
CN3
Connection for pressure sensor
CN4
Connection for SV6 valve
CN5
Connection for 4-way valve
CN6
Connection for compressor-electric heater band 1
CN7
Connection for outlet temperature sensor
CN8
Connection for outdoor temperature sensor and condenser
CN9
temperature sensor
Input connection for the neutral conductor
CN10
Input connection for the live cable
CN11
Connection for high pressure switch
CN13
Connection for low pressure switch
CN14
Connection for electric heater band of the casing (optional)
CN16
Communication connection for PCB A
CN17
Connection for compressor-electric heater band 2
CN18
Reserve
CN19
Reserve
CN20
Reserve
CN21
Reserve
CN22
Input connection for +12V/9V
CN24
Reserve
CN26
Output port N to PCB A
CN27
Output port L to PCB A
CN28
Communication connection for Hydrobox control card
CN29
Communication connection (reserved)
CN30
Connection for electronic expansion valve
CN33
Reserve
CN36
Reserve
CN37
Reserve
CN38
Connection for earthing wire
PE1
Connection for earthing wire
PE2
www.dimplex.de
Inverter board for 3-phase
CN1
CN2
CN5
CN7
CN8 (CN9)
CN15
CN16
CN17
CN18
CN19
CN20
CN22
CN23
Filter board for 3-phase
CN8
CN30
CN200
CN201
CN202
CN203
CN204
CN205
CN206
CN211
CN212
CN213
CN214
PE1
PE2
PE3
Main control board for 3-phase
CN4
CN5
CN6
CN7
CN8
CN9
CN10
CN11
CN13
CN16
CN18
CN19
CN20
CN21
CN22
CN24
452172.66.05-EN · FD 0306
Input connection P_in for IPM module
Communication connection for PCB C
Input connection P_out for IPM module
Power supply input connection L3
Input connection N for the rectifier bridge
Power supply input connection L3
Power supply input connection L1
Compressor connection U
Compressor connection W
Compressor connection W
Output connection for +15V
PED board
Connection for high pressure switch
Communication connection for PCB
Power supply connection for main control board
Power supply L3
Power supply L2
Power supply L1
Power supply N
Power filtering L3
Power filtering L2
Power filtering L1
Reserved
Power supply connection of 310VDC
Connection for fan throttle
Power supply connection for inverter module
Connection for earthing wire
Connection for earthing wire
Earthing wire
Communication connection for PCB C
Connection for room temperature sensor Th
Connection for pressure sensor
Connection for electric heater band 2
Connection for temperature sensor Tp
Connection for outdoor temperature sensor and condenser
temperature sensor
Connection for electric heater band 1
Reserved
Connection, 4-way valve
Connection for 2-way valve 5
Reserved
Connection for electric expansion valve
Communication connection for Hydrobox control card
English
EN-53