Transient voltage interruptions
Additional information
More information about recommended power supply units and tables for calculating the current
drawn for SINAMICS S120 module lineups can be found in the:
• SINAMICS S120 Booksize Power Units Manual
8.6

DRIVE-CLiQ components

8.6.1

Application

The components of the SINAMICS S120 drive family and the NCU are interconnected using
DRIVE-CLiQ. When connecting the components, please follow the rules in the documentation
below without exception:
The "Communication in the system" chapter of the "Machine configuration guidelines" System
Manual.
Properties
• Automatic detection of components
• 24 V / 450 mA per DRIVE-CLiQ interface is provided for the connection of encoders and
measuring systems
DRIVE-CLiQ pin assignment
Table 8-5
PIN
1
2
3
4
5
6
7
NCU 1750
Equipment Manual, 01/2022, A5E45627807B AE
Duration of overvoltage
Recovery time
Events per hour
Outage time
Recovery time
Events per hour
DRIVE-CLiQ interface X100 - X105
Signal name
Signal type Meaning
TXP
O
TXN
O
RXP
I
-
-
-
-
RXN
I
-
-
≤ 500 ms
≥ 50 s
≤ 10
≤ 3 ms
≥ 10 s
≤ 10
Transmit data +
Transmit data -
Receive data +
Reserved, do not use
Reserved, do not use
Receive data -
Reserved, do not use