Siemens SINUMERIK ONE NCU 1750 Equipment Manual page 125

Hide thumbs Also See for SINUMERIK ONE NCU 1750:
Table of Contents

Advertisement

Internal supply voltage (P24OUT)
The internal power supply for the digital inputs (X111, X222, X333: Pin 2) is derived from the
general power supply of module X1, pin 2 (P24).
Technical data
Table 12-24
Digital inputs
High-level voltage (U
Input current I
Low-level voltage (U
Signal delay time T
Digital outputs
Characteristics
• No galvanic isolation.
• Protection against: Short-circuit, overtemperature, and loss of ground.
• Automatic disconnection in case of undervoltage.
Terminal assignment for the digital outputs
The following figure shows an example of the terminal assignment for the digital outputs on
connector X111. Connectors X222 and X333 are assigned analogously.
NCU 1750
Equipment Manual, 01/2022, A5E45627807B AE
Electrical specification of the digital inputs:
)
H
at V
IN
H
)
L
PHL
:
:
:
:
1
(M)
Connectable components
min.
max.
15 V
30 V
2 mA
15 mA
-3 V
5 V
0.5 ms
3 ms
12.2 PP 72/48D PN
Nominal
24 V
-
0 V
-
125

Advertisement

Table of Contents
loading

Table of Contents