Mounting - Siemens SINUMERIK ONE NCU 1750 Equipment Manual

Hide thumbs Also See for SINUMERIK ONE NCU 1750:
Table of Contents

Advertisement

Connectable components
12.2 PP 72/48D PN
Name
Designation
H2
PNSync
H3
PNFault
H4
DIAG1
H5
DIAG2
H6
OVTemp
Note
When the system is booting, LEDs H1, H2 and H3 are lit.
12.2.2

Mounting

The I/O module can be fastened to the wall of the control cabinet using a mounting plate and M6
screws. The module must be installed according to EN 60204.
NOTICE
The I/O module can be damaged if there is no ground connection
A protective conductor must be connected using the grounding screw.
Note
The type plate is fitted to the rear side of the mounting plate. Note the relevant data because it
is no longer visible after installation.
114
Color
Description
Green
Lit: Task system is synchronized to the bus cycle clock.
Off: Task system is not synchronized to the bus cycle clock.
Flashes 0.5 Hz: Task system has synchronized to the bus cycle clock and cyclic data ex‐
change is running.
Red
Off: Module is operating without error.
Lit: A system error has occurred (faulty module, incorrect parameterization by the PROFI‐
NET controller, etc.).
Green
Reserved
Green
Reserved
Red
Overtemperature display
Equipment Manual, 01/2022, A5E45627807B AE
NCU 1750