Stay Arming The System With The Keypad; Silent Exit Delay - DSC neo HS2128 E User Manual

Alarm panel
Hide thumbs Also See for neo HS2128 E:
Table of Contents

Advertisement

Chapter
4
4.
After successfully initiating the arming sequence the:
Armed
indicator turns on.
l
Ready
indicator remains lit.
l
Exit Delay timer begins counting down.
l
Keypad beeps six times, continues beeping once per second
l
until beeping rapidly in the final ten seconds.
The system may be configured to have a persistent exit delay that
l
only ends when the exit door is opened and closed, or when a
button is pressed outside the protected premises.
5.
To cancel the arming sequence, enter your [access code] or present
your proximity tag to the keypad reader.
6.
Once the exit delay timer expires, thereby arming the system, the:
Ready indicator turns off.
l
Armed indicator remains on.
l
Keypad stops sounding.
l
NOTE: The installer configures the exit delay timer and whether or not an access code is required for arm-
ing the system.

4.2 Stay Arming the System with the Keypad

Stay mode partially activates your alarm system by:
Arming all perimeter sensors.
l
Bypassing all interior sensors.
l
To Arm the System in Stay mode:
1.
Ensure all windows and doors are closed and that the Ready indicator
is on.
2.
Press and hold the Stay key for 2 seconds and, if required, enter your
access code or present your proximity tag. Do not leave the premises.
3.
If zones have been bypassed, ICN or LED keypads bypass LED will
light and the bypassed zones numbers will be shown. On an LCD
keypad a warning appears.
4.
After successfully initiating the arming sequence the:
Armed
indicator turns on.
l
Ready
indicator remains lit.
l
Exit Delay timer begins counting down.
l
5.
To cancel the arming sequence, enter your [access code] or present
your proximity tag.
6.
Once the exit delay timer expires, thereby arming the system, the:
Ready
indicator turns off.
l
Armed
indicator remains on.
l
Bypass or system indicator activates.
l
NOTE: When using a proximity tag and a Stay/Away zone is programmed, the system arms in Away
mode if a delay zone is tripped. If there is no Stay/Away zone, the system always arms in Away mode.

4.2.1 Silent Exit Delay

If the system is armed using the Stay key
The warning beep is silenced.
l
The exit time is doubled for that exit period only (CP-01 versions only).
l
NOTE: For non CP-01 versions, Standard Exit Time is used.
or the No Entry Arming method [*][9]:
-
-
11
Exit Delay in
Progress
System Disarmed
No Alarm Memory
System Armed
in Away Mode
LCD Display
Date Time
JAN 02/18 2:06a
System is
Ready to Arm
then
Enter Your
Access Code
* Warning *
Bypass Active
Exit Delay in
Progress
System Disarmed
No Alarm Memory
System Armed
in Stay Mode

Advertisement

Table of Contents
loading

Table of Contents