WARM-UP CYCLES: For a typical daily start-up, it is recommended to run the machine through 3 cycles
to ensure that all of the cold water is out of the system and to verify that the unit is operating correctly. To
cycle the machine, ensure that the power is on and that the tub has filled to the correct level.
Push the START CYCLE button and hold until the green cycle light is on and then release, the unit will
start, run through the cycle, and shut off automatically. Repeat this two more times. The unit should now be
ready to proceed with the washing of ware.
WASHING A RACK OF WARE: To wash a rack, open the door completely and slide the rack into the unit.
Close the door, press the START CYCLE button and hold until the green cycle light is on and release, the unit
will start. Once the cycle is completed, open the door and remove the rack of clean ware. Replace with a rack
of soiled ware and close the door. The process will then repeat itself.
OPERATIONAL INSPECTION: Based upon usage, the pan strainer may become clogged with soil and
debris as the workday progresses. Operators should regularly inspect the pan strainer to ensure it has not
become clogged. If the strainer does, it will reduce the washing capability of the machine. Instruct operators
to clean out the pan strainer at regular intervals or as required by work load.
SHUTDOWN AND CLEANING: At the end of the workday, close the door. Start a cycle. Wait approxi-
mately five seconds after the green cycle light comes on and then push the POWER OFF switch. This will put
the machine in shutdown mode which will let the machine drain completely prior to shutting off. Once the
wash tub is drained and power light is off, remove he pan strainer. Remove soil and debris from the strainer
and set to the side. Unscrew the wash and rinse arms from their manifolds. Remove the end caps and flush
the arms with water. Use a brush to clean out the inside of the arms. If the nozzles appear to be clogged, use
a toothpick to remove the obstruction. Wipe the inside of the unit out, removing all soil and scraps. Reas-
semble the wash and rinse arms and replace them in the unit. The arms only need to be hand tight, do not
use tools to tighten them down. Reinstall the strainer and close the door.