PROGRAMMING INSTRUCTIONS FOR CHEMICAL FEEDER PUMPS (INSTALLATION TECHNICIAN ONLY)
To access the programming mode, the machine must be ON and idle (between cycles).
On the timer board, press and hold both the MOVE and ENTER buttons on the timer board simultane-
ously for two seconds.
The PROGRAM (PGM) light and light A will illuminate.
NOTE: Once in the programming mode, the MOVE button is used to scroll between the programming
categories and the ENTER button is used to select the category.
Press the MOVE button to move the solid light to the desired location of FILL, RINSE AID, DETERGENT,
or SANITIZER. Please note that options A, B, C and D are not adjustable outputs.
Press the ENTER button for the chosen category. Now, the (PGM) light will illuminate along with lights
corresponding to the time values for the chosen category. The ACCEPT light will blink.
The PROGRAM light will illuminate.
To change the value of a parameter, use the MOVE button to illuminate the light next to the time option
(time is measured in seconds). In the time categories, each second in use will light up. To deselect the option,
press ENTER and the light will go off, press ENTER again and it will illuminate. Once you have set your time
catergory, press the MOVE button until the ACCEPT light illuminates and press ENTER. This will save the
changed parameters.
Once you press the ENTER button when the ACCEPT light is blinking you will exit the programming
mode. To change any other values, you will have to return to the programming mode. To revert back to a
previous setting, you must return to that option and change the parameter back to the previous setting.
Once in the programming mode, if there have been no keypad inputs for approximately two minutes,
the system will automatically exit out of the programming mode. Any changes to parameters will be saved
when the programming mode is automatically exited.
The wash and drain cycles are not adjustable.
All time adjustments are in seconds. Refer to the chart on the following page for adjustable outputs.