9 Settings
9.5

Reading counters

Fig.64
Accessing the counter menu
F1 F1 F1
F2 F3 F4
Tab.32
List of counters (read only)
Meters
Level
AC001
User
AC016
Installer
AC002
Installer
AC003
Installer
AC004
Installer
AC005
User
AC006
User
AC026
Installer
AC027
Installer
CLR
Installer
DC001
Installer
DC002
Installer
DC003
Installer
DC004
Installer
DC005
Installer
GC007
User
PC001
Installer
PC002
Installer
PC003
Installer
PC004
Installer
Proceed as described below to access the counter menu:
Press the F3 key;
The
Turn the knob
to confirm;
Turn the
key to confirm;
To access the meters at the installer level, turn the
reach the SVC symbol then press the F4 key to confirm;
Use the
key
Turn the
key to confirm;
press F1 to exit.
Description
Number of boiler power supply hours
Filling counter, counts the amount of filling cycles
Number of boiler operating hours after last maintenance operation
Number of boiler power supply hours after last maintenance operation
Failed start-up attempts after last maintenance operation
Indicative energy consumption [kW/h] in heating mode
Indicative energy consumption [kW/h] in domestic hot water (DHW) mode
Number of pump operating hours
Number of pump start-ups
Resetting of all meters (to be confirmed by pressing the F4 key)
NOTE: This parameter is only displayed if AP010 ≠ 0
Total energy consumption used by domestic hot water (DHW)
Number of domestic hot water cycles (three-way valve switching)
Number of hours in domestic hot water mode (three-way valve switching)
Number of burner start-ups for domestic hot water mode
Number of burner start-up hours for domestic hot water mode
Failed start-up attempts
Indicative electrical energy consumption [kW/h] in heating mode
Number of burner start-ups for heating and domestic hot water mode
Number of burner start-up hours for heating and domestic hot water mode
Burner flame leaks
symbol flashes on the display;
until the
symbol appears, then press the F4 key
knob until you reach the required counter, then press the F4
knob to enter code 0012 and confirm by pressing the F4
knob until you reach the required counter, then press the F4
knob until you