Connecting The Condensate Drain; Air Supply/Flue Gas Connection; Connecting The Flue/Chimney - Baxi 800 Combi 2 Series Installation And Service Manual

High-efficiency wall-hung condensing gas boiler
Hide thumbs Also See for 800 Combi 2 Series:
Table of Contents

Advertisement

6 Installation
Fig.33
Pour 300ml of water into flue spigot
6.3
Air supply/flue gas connections
Fig.34
Telescopic flue
1
2
Fig.35
Flue dimension X
X
40
800 Combi 2
6. The pipework must be clipped at suitable intervals to support it, com­
6.2.2
1. Remove the blanking cap, and using the straight rubber coupling
2. The straight rubber coupling will accept 21.5 mm (
PN-0000602
6.3.1
When installing internal fit telescopic flue & elbow kits 7778296 &
7778299 refer to the instructions supplied with them.
HORIZONTAL TELESCOPIC FLUE 720598701 (concentric 60/100)
1
2
3
3
There are two telescopic sections, the terminal assembly and the connec-
tion assembly, a roll of sealing tape and two self tapping screws. A 93° el-
bow is also supplied.
The two sections can be adjusted to provide a length between 315 mm
and 500 mm when measured from the flue elbow (there is 40 mm
engagement into the elbow).
1.
2.
3.
4. In instances where the dimension " X" is between 250 mm and
X
mencing as close to the boiler as possible.

Connecting the condensate drain

supplied, connect the condensate drain pipework to the boiler con­
densate trap outlet pipe.
See
Ensure the discharge of condensate complies with any national or
local regulations in force (see HHIC recommendations).
See
Condensate drain, page 27.
over-flow pipe which should generally discharge internally into the
house-hold drainage system. If this is not possible, discharge into
an out-side drain is acceptable.
Important
The boiler condensate trap should be primed by pouring
approximately 300 ml of water into the flue spigot. Do not allow
any water to fall into the air inlet.

Connecting the flue/chimney

315 mm to 500 mm
Connection assembly
Terminal assembly
Locate the flue elbow on the adaptor at the top of the boiler. Set the
elbow to the required orientation.
Important
The flue elbow is angled at 93° to ensure a fall back to the boiler.
Measure the distance from the outside wall face to the elbow. This
dimension will be known as " X" .
If the distance from the flue elbow to the outside face of the wall is
less than 250 mm the connection assembly can be discarded and
the terminal assembly fitted directly into the elbow.
315 mm it will be necessary to shorten the terminal assembly by
careful cutting to accommodate walls of these thicknesses.
3
/
in) plastic
4