Service Settings - Baxi 800 Combi 2 Series Installation And Service Manual

High-efficiency wall-hung condensing gas boiler
Hide thumbs Also See for 800 Combi 2 Series:
Table of Contents

Advertisement

* When using mixes that are up to 20% hydrogen (H
800 Combi 2
50
7.4.4

Service settings

), for calibrating the gas valve only refer to the value of O
2
Important
This appliance is suitable for G20 gas containing up to
20% hydrogen (H
of H
, the percentage of O
2
example: 20% of H
increase of O
need to be adjusted more accurately. This must be
adjusted using standard O
). Due to variations in the percentage
2
may vary over time. (For
2
in the gas may lead to a 1.5%
2
in the flue gases) The gas valve may
2
values for the gas used.
2
7 Commissioning
%.
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

824 combi 2830 combi 2836 combi 2

Table of Contents