TO THE INSTALLER

Air-Cooled Machines

Do not obstruct air intake and discharge openings; a
minimum 6 in. (152 mm) air space is required on both
sides and 1 in. (25 mm) at rear. This will allow for
adequate air flow across the condenser. Failure to allow
adequate clearance can reduce the refrigeration capacity
of the freezer and possibly cause permanent damage to
1
the compressor.

Water Connections

Water-Cooled Machines Only
An adequate cold water supply must be provided with a
hand shutoff valve. On the underside rear of the base
pan, two 3/8 in. I.P.S. water connections for inlet and
outlet have been provided for easy hookup. Water lines
connected to the machine should have 1/2 in. (13 mm)
inside diameters. (Flexible lines are recommended, if
local codes permit.) Depending on local water conditions,
it may be advisable to install a water strainer to prevent
foreign substances from clogging the automatic water
valve. There will be only one water-in and one water-out
connection. Do not install a hand shutoff valve on the
water-out line! Water should always flow in this order:
first, through the automatic water valve; second, through
the condenser; and third, through the outlet fitting to an
open trap drain.
IMPORTANT! A backflow prevention device is
required on the incoming water connection side. Please
see the applicable national, state, and local codes for
determining the proper configuration.
1-2

Electrical Connections

Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
freezer for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications. Refer
to the wiring diagram provided inside the electrical box
for proper power connections.
In the United States, this machine is intended to be
installed in accordance with the National Electrical Code
(NEC) ANSI/NFPA 70-1987. The purpose of the NEC
code is the practical safeguarding of persons and
property from hazards arising from the use of electricity.
This code contains provisions considered necessary for
safety. Compliance therewith and proper maintenance
will result in an installation essentially free from hazard!
In all other areas of the world, this machine should be
installed in accordance with the existing local codes.
Please contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES.
WARNING! This machine must be properly
grounded! Failure to do so can result in severe personal
injury from electrical shock!
IMPORTANT! This machine is provided with
an equipotential grounding lug that is to be properly
attached to the rear of the frame by the authorized
installer. The installation location is marked by the
equipotential bonding symbol (5021 of IEC 60417-1) on
the removable panel and the machine's frame.
Model 0736
To the Installer