11 Remove the control panel to access the gas control valve. The stepper motor (adjustable regulator)
has an installation sheet included with it – make sure to follow all of the directions. Place the stepper
motor on the gas control valve (see pictures below) – MAKE SURE IT IS CORRECTLY ORIENTED.
Secure using the screws included with the motor – tighten to 25 Lb-inches. Leak test this area after
installation to verify proper installation.
NOTE: Install the identification label that is included with the conversion kit, to the valve body where it
can be easily seen.
11 Restore the appliance to the correct configuration. Make the gas line connection, bleed the gas line
(if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve.
NOTE: See page 29 for information regarding proper operation of the appliance. Test all functions
described in the operation section to verify that everything is operating as expected.