Bnc Accessories - National Instruments X Series User Manual

Hide thumbs Also See for X Series:
Table of Contents

Advertisement

Note (NI 6346/6349/6356/6358/6366/6368/6374/6376/6378/6386/6396
Devices)
Note (NI 6345/6355/6365/6375 Devices)

BNC Accessories

You can use the SHC68-68-EPM shielded cable, to connect your DAQ device to the BNC
accessories listed in Table 2-1.
BNC Accessory
BNC-2110
BNC-2111
BNC-2120
BNC-2090A
BNC-2115
*
The BNC-2111 cannot be used with NI 6356/6358/6366/6368/6374/6376/6378/6386/6396 SMIO
X Series devices.
The BNC-2115 can only be used on connectors 1, 2, or 3 of NI 6345/6355/6365/6375 devices and
connector 1 of the NI 6349 device.
Simultaneous MIO X Series devices do not support SCC.
Table 2-1. BNC Accessories
*
SCC is supported only on Connector 0.
Description
Provides BNC connectivity to all analog
signals, some digital signals, and spring
terminals for other digital signals
Provides BNC connectivity to
16 single-ended analog input signals,
two analog output signals, five DIO/PFI
signals, and the external reference voltage
for analog output
Similar to the BNC-2110, and also has a
built-in function generator, quadrature
encoder, temperature reference, and
thermocouple connector
Desktop/rack-mountable device with
22 BNCs for connecting analog, digital, and
timing signals
Provides BNC connectivity for
24 differential or 48 single-ended analog
inputs for connectors 1, 2, or 3 of the
NI 6345/6355/6365/6375 devices. This
leaves 8 differential or 16 single-ended
analog inputs inaccessible on
connectors 1, 2, or 3. Provides BNC
connectivity for
24 differential analog inputs for connector 1
of the NI 6349 device.
© National Instruments | 2-5
X Series User Manual

Advertisement