Connecting Analog Output Signals

AO <0..3> are the voltage output signals for analog output channels 0, 1, 2, and 3. AO GND is
the ground reference for AO <0..3>.
Figure 5-2 shows how to make analog output connections to the device.
+
V OUT
Load
Load
V OUT
Connector 0 (AI 0 –15)

Analog Output Timing Signals

Figure 5-3 summarizes all of the timing options provided by the analog output timing engine.
100 MHz Timebase
DSTAR <A..B>
PFI, RTSI
PXI_STAR
Analog Comparison
Event
20 MHz Timebase
100 kHz Timebase
PXI_CLK10
X Series devices feature the following analog output (waveform generation) timing signals:
AO Start Trigger Signal
AO Pause Trigger Signal
AO Sample Clock Signal
AO Sample Clock Timebase Signal
Figure 5-2. Analog Output Connections
Analog Output Channels
AO 0
Channel 0
AO GND
AO 1
Channel 1
X Series Device
Figure 5-3. Analog Output Timing Options
AO Sample Clock
Timebase
*
*
*
+
V OUT
Load
Load
V OUT
Connector 1 (AI 16– 31)
DSTAR <A..B>
PFI, RTSI
PXI_STAR
Analog Comparison Event
Ctr n Internal Output
Programmable
Clock
Divider
X Series User Manual
Analog Output Channels
AO 2
Channel 2
AO GND
AO 3
Channel 3
X Series Device
AO Sample Clock
© National Instruments | 5-5