18.4
Cleaning the oil screen in the oil tank
Note
Environmental hazard Hazardous substances cause environmental damage.
–
Dispose of oils, grease, filters, fuel, cleaning agents, brake fluid, etc., correctly and in compliance with
the applicable regulations.
–
Plug in wake-up connector
diagnostics connector
The combination instrument lighting is activated.
Info
The connector is included as part of the motorcycle's
separate enclosure.
–
Wait for at least five seconds.
–
Release the fixing means from the throttle grip.
The oil pump is timed.
Info
The oil pump is actuated at various speeds.
The procedure is clearly audible.
–
Wait until you can no longer hear the oil pump operating.
–
Disconnect the wake-up connector from the diagnostics con-
nector.
S04854-11
–
Check whether air bubbles are visible in the hose
»
If air bubbles are visible:
–
Repeat the entire procedure until air bubbles are no
longer visible.
–
Mount the diagnostics connector on the holder.
–
Mount the EFI control unit on the rubber lugs.
S03513-10
Finishing work
–
Mount the seat. (
Preparatory work
–
Raise the motorcycle with a lift stand. (
–
Remove main silencer. (
–
Remove the seat. (
–
Remove the fuel tank.
–
Remove the air filter box cover. (
SERVICE WORK ON THE ENGINE 18
4
for priming the oil pump to the
5
.
p. 78)
p. 64)
p. 82)
p. 78)
(
p. 83)
p. 79)
6
.
143