Master Feed
8. Remove the thermal head slowly.
• If you cannot access SP modes, open the master making unit and loosen the 2 screws [D].
Installation
1. Insert the tabs (1) at the operation side and the middle.
2. Turn the thermal head counterclockwise and insert the tab (2) at the front.