Final Connections - Countertop Installation

1 . Use 1/4" OD tubing to plumb incoming water (above countertop) to the fitting on the rear of the dispenser
(Fig . 8 .1) .
2 . Mount the Flood Prevention Valve bracket inside the cabinet . Refer to the instructions included with the
Flood Prevention Valve and set the Valve to the "2" position using the included key .
3 . Use 1/4" OD tubing to plumb incoming water (below countertop) to the Flood Prevention Valve, assuring
the correct length so that it snaps into the mounting bracket (note proper flow direction) (Fig . 8 .2) .
4 . Plumb to the Water Pressure Regulator (Fig . 8 .3) .
5 . Then plumb to the Chiller/Carbonator (Fig . 8 .4) assuring there is enough line that the Chiller/Carbonator
can be removed and set in front of the cabinet . Note proper flow direction for the devices and the Flood
Prevention Valve must be mounted vertically .
6 . Remove the right side panel of the dispenser (see Page 24) to expose the Chiller/Carbonator connections .
7 .
Install the insulated Sparkling and Chilled Still water lines and the power cord to the dispenser, routing the
lines down through the cutout in the countertop (Fig . 8 .5) .
Note: Water lines are supplied at 6 ft (1 .83 m) lengths . Note the Chilled Still water is 3/8" OD tubing and the
Sparkling water is 1/4" OD tubing .
8 . Install the plug in the center Ambient Water Out of the Chiller/Carbonator (Fig . 8 .6) .
9 . Connect the Chilled Still water 3/8" OD tubing to the Chiller/Carbonator (Fig . 8 .7) .
10 . Connect the Sparkling water 1/4" OD tubing to the Chiller/Carbonator (Fig . 8 .8) .
11 . Install the tube fitting and flare washer onto the CO
the CO
tank . Make sure that the CO
2
according to local codes . Installing an OSHA approved cylinder rack with chain in an adjacent cabinet with
easy access for cylinder change-outs is recommended .
12 . Install 1/4" OD LLDPE tubing from the regulator to the back of the Chiller/Carbonator (Fig . 8 .9) .
13 . Leave the shutoff valve in the OFF position and open the cylinder valve . Using a flat blade screwdriver
adjust the CO
pressure to 60 psi on the top gauge . (The CO
2
responsibility of the customer .)
14 . Turn on water and leave CO
15 . Plug in the dispenser but do not turn Chiller/Carbonator on at this point .
16 . Dispense 1 liter Still water from the dispenser, then dispense 1 liter Sparkling water (Note: At this point,
the water will not be carbonated) .
17 . Remove the screw from the Chiller/Carbonator top panel (Fig . 8 .10) and remove top panel (Fig . 8 .11) .
18 . Pull the Chiller/Carbonator safety valve ring (Fig . 8 .12) until water starts to come out of the side of the
fitting and release immediately . It may take up to a minute for water to run from the safety valve . Reinstall
Chiller/Carbonator top panel .
Note: This procedure is required to remove an air bubble upon initial installation which can prevent the machine
from functioning properly . If air is trapped, the carbonation pump will continue running and eventually fault .
This requires a power cycle to reset .
19 . Open the CO
valve on the CO
2
Carbonator . Make sure the thermostat on the front of the Chiller/Carbonator is set to the coldest position
(7) . Dispense Sparkling water until you hear the Chiller/Carbonator pump turn on (Note: the pump is very
quiet) . The pump should turn off again within a few seconds depending on how much carbonated water
is dispensed . Perform at least 3 dispenses to cycle the pump and assure there is no trapped air in the
system .
20 . Install Chiller/Carbonator cradle into cabinet . Slide Chiller/Carbonator into cabinet between the cradle
opening and assure the Chiller/Carbonator exhaust shroud is located above the cutout in the toe-kick
recess . Allow 2-4 hours for the Chiller/Carbonator to reach temperature .
14
Sparkling Water and Ice Dispenser 7CI100A/7FS100A, 15CI100A/15FS100A
2
tank is installed in a location with appropriate tipping prevention
2
off . Make sure all water valves are open and check for leaks .
2
regulator and turn ON the power switch on the front of the Chiller/
2
regulator . Install the CO
2
cylinder is not supplied and is the
2
pressure regulator onto

Advertisement

Table of Contents
loading

This manual is also suitable for:

7fs100a15ci100a15fs100a7ci100aK46456

Table of Contents