Final Connections - Freestanding Installation

1 . Mount the Flood Prevention Valve bracket to the rear of the base stand (Fig . 9 .1) .
2 . Refer to the instructions included with the Flood Prevention Valve and set the Valve to the "2" position
using the included key .
3 . Use 1/4" OD tubing to plumb incoming water to the tee fitting (Fig . 9 .2) .
4 . Use 1/4" OD tubing to plumb from the tee fitting to the fitting on the rear of the dispenser (Fig . 9 .3) .
5 . Use 1/4" OD tubing to plumb from the tee to the Flood Prevention Valve, assuring the correct length so
that it snaps into the mounting bracket (note proper flow direction) (Fig . 9 .4) .
6 . Use 1/4" OD tubing to plumb to the Water Pressure Regulator (Fig . 9 .5) .
7 .
Then plumb to the Chiller/Carbonator (Fig . 9 .6) assuring there is enough line that the Chiller/Carbonator
can be removed and set in front of the base stand .
8 . Remove the right side panel of the dispenser (see Page 24) to expose the Chiller/Carbonator connections .
Cut a 1 .25" length of the rubber edging . Install the 1 .25" length on the short edge of the base stand pass
through (Fig . 9 .7) and the remaining 6 .75" length on the long edge (Fig . 9 .8) .
9 . Install the insulated Sparkling and Chilled Still water lines and the power cord to the dispenser, routing the
lines down through the base stand (Fig . 9 .9) .
Note: Water lines are supplied at 6 ft (1 .83 m) lengths, but can be trimmed to 4 ft length for freestanding
applications . Note the Chilled Still water is 3/8" OD tubing and the Sparkling water is 1/4" OD tubing .
10 . Install the plug in the center Ambient Water Out of the Chiller/Carbonator (Fig . 9 .10) .
11 . Connect the Chilled Still water 3/8" OD tubing to the Chiller/Carbonator (Fig . 9 .11) .
12 . Connect the Sparkling water 1/4" OD tubing to the Chiller/Carbonator (Fig . 9 .12) .
13 . Install the tube fitting and flare washer onto the CO
the CO2 tank . Make sure that the CO
according to local codes . Installing an OSHA approved cylinder rack with chain in an adjacent cabinet with
easy access for cylinder change-outs is recommended .
14 . Install 1/4" OD LLDPE tubing from the regulator to the back of the Chiller/Carbonator (Fig . 9 .13) .
15 . Leave the shutoff valve in the OFF position and open the cylinder valve . Using a flat blade screwdriver
adjust the CO
pressure to 60 psi on the top gauge . (The CO
2
responsibility of the customer .)
16 . Turn on water and leave CO
17 . Plug in the dispenser but do not turn Chiller/Carbonator on at this point .
18 . Dispense 1 liter Still water from the dispenser, then dispense 1 liter Sparkling water (Note: at this point,
the water will not be carbonated) .
19 . Remove the screw from the Chiller/Carbonator top panel (Fig . 9 .14) and remove top panel (Fig . 9 .15) .
20 . Pull the Chiller/Carbonator safety valve ring (Fig . 9 .16) until water starts to come out of the side of the
fitting and release immediately . It may take up to a minute for water to run from the safety valve . Reinstall
Chiller/Carbonator top panel .
Note: This procedure is required to remove an air bubble upon initial installation which can prevent the machine
from functioning properly . If air is trapped, the carbonation pump will continue running and eventually fault .
This requires a power cycle to reset .
21 . Open the CO
valve on the CO
2
Carbonator . Make sure the thermostat on the front of the Chiller/Carbonator is set to the coldest position
(7) . Dispense Sparkling water until you hear the Chiller/Carbonator pump turn on (Note: the pump is very
quiet) . The pump should turn off again within a few seconds depending on how much carbonated water
is dispensed . Perform at least 3 dispenses to cycle the pump and assure there is no trapped air in the
system .
22 . Install Chiller/Carbonator cradle into base stand . Slide Chiller/Carbonator into base stand between the
cradle opening and assure the Chiller/Carbonator exhaust shroud is located above the cutout in the base
stand . Install the front Chiller/Carbonator retaining brackets into the base stand and replace the base
stand cover . Allow 2-4 hours for the Chiller/Carbonator to reach temperature .
16
Sparkling Water and Ice Dispenser 7CI100A/7FS100A, 15CI100A/15FS100A
2
tank is installed in a location with appropriate tipping prevention
2
off . Make sure all water valves are open and check for leaks .
2
regulator and turn ON the power switch on the front of the Chiller/
2
regulator . Install the CO
2
cylinder is not supplied and is the
2
pressure regulator onto