Air Shutter Adjustment - Lopi 864 TV 40K CleanFace Installation Manual

Direct vent fireplace
Table of Contents

Advertisement

Finalizing the Installation
10. Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be
yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
Correct
Flames should be blue at the
base, yellow-orange on the top.
Air Shutter Adjustment
11. Adjust the flame to its highest position - the flames should not contact the top of the firebox. Check the flame on low
position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer
for a remedy.
12. Give this manual to the home owner for future reference and fully explain operation of this heater. For comprehensive
operating and maintenance instructions, refer to the Owner's Manual.
ACID WASH WARNING: Before installing the faceplate, make sure any masonry that has been treated with acid wash has
been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar.
If not properly neutralized with an ammonia solution, the plated face may develop a permanent tarnish when the acid
evaporates over time. Contact your dealer if uncertain your facing has been properly neutralized.
© Travis Industries
(for qualified installers only)
Not Enough Air
If the flames are too tall or sooty on the
ends, open the air shutter.
Rear Burner Air Shutter Control
Front Burner Air Shutter Control
NOTE: you may wish to use pliers to adjust the front air shutter. Typically,
the front air shutter is fully closed on NG, fully open on LP
6/28/2019 - 1499
Too Much Air
If the flames are all blue and
short, close the air shutter.
(GOLD)
Right = Less Air
Left = More Air
(RED)
Right = Less Air
Left = More Air
33
864 40K CF Install Aust

Advertisement

Table of Contents
loading

Table of Contents