Lopi Revere Owner's Manual
Hide thumbs Also See for Revere:
Table of Contents

Advertisement

SAFETY NOTICE:

If this appliance is not properly installed, a house
fire may result. For your safety, follow the
installation directions. Contact local building or
fire officials about restrictions and installation
inspection requirements in your area.
Revere Fireplace Insert
10850 117th Place N.E. Kirkland, WA 98033
Part # 93508033
$10.00
Revere
Owner's Manual
- October, 1998 -
¥ Masonry Fireplace
Insert
¥ Zero-Clearance (Metal)
Fireplace Insert
Listed

Advertisement

Table of Contents
loading

Summary of Contents for Lopi Revere

  • Page 1: Introduction And Important Information

    For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Revere Fireplace Insert Listed 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508033 $10.00...
  • Page 2: Safety Precautions

    AFETY RECAUTIONS ¥ The viewing door must be ¥ Gasoline or other closed and latched during flammable liquids must operation. never be used to start the fire or "Freshen Up" the ¥ Never block free airflow fire. Do not store or use through the air vents on gasoline or other this appliance.
  • Page 3 AFETY RECAUTIONS ONTINUED ¥ Never try to repair or ¥ Do not make any changes replace any part of this or modifications to an appliance unless existing masonry fireplace instructions are given in or chimney to install this this manual. All other appliance.
  • Page 4: Table Of Contents

    ABLE OF ONTENTS Introduction and Important Information Maintaining Your Appliance Introduction and Important Information ...... 1 Maintenance Schedule..........19 Safety Precautions............. 2 Remove Ash From The Firebox (If Necessary)..19 Clean The Viewing Glass (If Necessary) ....19 Clean The Brass (If Necessary) ......... 19 Features and Specifications Check For Creosote Buildup ........
  • Page 5: Features And Specifications

    EATURES AND PECIFICATIONS Installation Options: Features: ¥ Insert into a Masonry Fireplace ¥ EPA Phase II Approved ¥ 2.2 Cubic Foot Firebox Volume ¥ Insert into a Zero Clearance (Metal) Fireplace ¥ Single, Push/Pull Operating Control ¥ Accepts Logs Up to 18" Long ¥...
  • Page 6: Insert Installation

    NSERT NSTALLATION SAFETY NOTICE: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. ¥ Check with local building officials for any permits required for installation of this stove and notify your insurance company before proceeding with installation.
  • Page 7: Insert Placement Requirements

    NSERT NSTALLATION NSERT LACEMENT EQUIREMENTS (See the illustration below) ¥ The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the insert ¥ Insert and hearth must be installed on a level, secure floor ¥...
  • Page 8: Masonry Fireplace Requirements

    NSERT NSTALLATION ASONRY IREPLACE EQUIREMENTS ¥ Chimney must have a clay tile liner or a stainless steel liner (positive connection) ¥ Entire fireplace, including chimney, must be clean and not cracked or damaged. Any damage must be repaired prior to installation of the insert ¥...
  • Page 9: Block-Off Plate Installation

    NSERT NSTALLATION LOCK LATE NSTALLATION Whenever this appliance is installed with a direct connection a block-off plate, other non-combustible seal-off plate (e.g. damper adapter), will need to be installed. This device is used to seal the chimney, insuring no smoke enters the home and providing the chimney system with a seal to provide greater draft.
  • Page 10: Insert With Positive Connection

    NSERT NSTALLATION NSERT WITH Install a non-combustible Cap (prevents water OSITIVE cover plate to prevent water from entering) from entering the chimney ONNECTION NOTE: This installation may be used with a masonry or zero NOTE: Flue Liner clearance fireplace. The Most factory- requirements in the section The liner must be...
  • Page 11: Insert With Direct Connection (Z.c. Fireplace)

    NSERT NSTALLATION NSERT WITH NOTE: This installation may be IRECT used with a masonry or zero clearance fireplace. This ONNECTION illustration depictsw a zero (Z.C. clearance insert, all requirements IREPLACE in the section "Zero Clearance Stainless steel Fireplace Requirements" must be chimney connector fulfilled prior to installation.
  • Page 12: Operating Your Appliance

    PERATING PPLIANCE SAFETY NOTICE: If this appliance is improperly operated , a house fire may result. For your safety, read the directions below and the Safety Precautions listed on pages 2 and 3 prior to operating this appliance. ¥ If you have any questions regarding the operation of this appliance, contact your dealer. Building a fire in disregard of the information provided in this section can cause permanent damage to your appliance and void your warranty.
  • Page 13: Bypass Control

    PERATING PPLIANCE ONTINUED Bypass Control The bypass control is centered along the top of the appliance and is operated by pushing or pulling the control in or out. When the control is completely pulled out, the bypass allows the smoke to go directly up the flue, creating more draft for starting the appliance or reloading.
  • Page 14: How To Reload Your Appliance

    PERATING PPLIANCE ONTINUED How to Reload Your Appliance When reloading your appliance, you can avoid smoke entering the room by following the steps below: 1. Pull the air control all the way out until the fire starts to burn quickly, helping draft. 2.
  • Page 15: How To Obtain An Overnight Burn

    PERATING PPLIANCE ONTINUED How to Obtain an Overnight Burn An overnight burn of 10 hours may be obtained with a small amount of coals left over in the morning if the right steps are taken. 1. Establish a hot fire. 2.
  • Page 16: Blower Operation

    PERATING PPLIANCE ONTINUED LOWER PERATION The optional front blower is available to assist the convection chamber in distributing heat to your home. The directions below detail the options you have with the blower and the best method for operation. When to turn the blower on The blower should be left off for the first 30 minutes of starting the appliance.
  • Page 17: A Word About Wood

    PERATING PPLIANCE ONTINUED ORD ABOUT This appliance is designed to burn natural cord wood with high efficiencies and low emissions. With properly dried wood, you will fully realize the heating and clean-burning potential of our high- technology appliance. With poor wood, this high-technology appliance will become much less efficient and produce more emissions.
  • Page 18 PERATING PPLIANCE ONTINUED ORD ABOUT ONTINUED Sheet Metal Roofing 2x4 Purlins 2x6x12 Rafter Constructing a Wood Shed 2x8x8' Girder The drawing to the right details the 4x4x2 Posts Spaced 8' Apart construction of an inexpensive wood shed Siding and Girts (Optional) that will promote drying, increasing the heat output from your wood.
  • Page 19: Maintaining Your Appliance

    AINTAINING PPLIANCE AINTENANCE CHEDULE Your appliance requires periodic maintenance to work correctly. The steps involved with maintenance are usually quick and easy. Look through this maintenance schedule and plan accordingly. WARNING: Failure to properly maintain and inspect your appliance may reduce the performance and life of the appliance, void your warranty, and create a fire hazard.
  • Page 20: Door And Glass Inspection

    AINTAINING PPLIANCE ONTINUED LASS NSPECTION The door must seal air-tight for the appliance to work correctly. Check the two items below and follow the appropriate remedy to fix any problems. ¥ Check the door cam operation. When closed, the door cam should pull the door against the face of the appliance, but not be so tight as to not allow the handle to point downwards.
  • Page 21: Replacing The Door Gasket

    AINTAINING PPLIANCE ONTINUED Replacing the Door Gasket Remove the door by opening it and lifting it off the hinges. Remove the old gasket by stripping it away with a screwdriver or other tool (see the illustration below). Apply a line of gasket cement (available from your dealer) in the groove that follows the perimeter of the door.
  • Page 22: Touch-Up Paint

    AINTAINING PPLIANCE ONTINUED OUCH AINT Included with the owner's pack of this appliance is a can of Stove-BriteÒ paint. To touch up nicks or dulled paint, apply the paint while the appliance is cool. Use 120 grit sandpaper (clean with water and dry with a piece of cloth) if the surface requires smoothing.
  • Page 23: Firebrick Removal And Replacement Inst

    AINTAINING PPLIANCE ONTINUED Firebrick Removal and Replacement Instructions With the appliance cool, remove all ash from the firebox. Only the firebrick that is damaged must be replaced. If the damaged firebrick is on the floor, it can be replaced by simply removing the firebrick in front of it.
  • Page 24 AINTAINING PPLIANCE ONTINUED Baffle Removal and Replacement Instructions (continued) All of the baffle components are removable to facilitate easy cleaning and repairs. Make sure the appliance is cool before removing any of the components. See the instructions on the following page for removing the secondary air tubes.
  • Page 25: Secondary Air Tube Replacement Instructions

    AINTAINING PPLIANCE ONTINUED Secondary Air Tube Replacement Instructions REMOVING THE Secondary Air Pry out both pins on the secondary SECONDARY AIR TUBES Tube Sleeve air tube sleeve (use a screwdriver). Follow the directions to the right. To remove the front tube, the baffle firebricks and front baffle support must be removed first.
  • Page 26: Troubleshooting

    ROUBLESHOOTING Problem: Possible Cause: Remedy: Smoke Spills From ¥ Door was opened before the air Pull the air control all the way out a few seconds before Door When control was pushed in opening the door. Loading ¥ Door was opened before the Pull the bypass all the way out before opening the door bypass was pulled out (see "Bypass Control"...
  • Page 27: Warranty

    ARRANTY To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 10850 117th Place N.E., Kirkland, Washington 98033. TRAVIS INDUSTRIES, INC. warrants this appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows: Years 1 &...
  • Page 28: Listing Information

    RODUCT ISTING NFORMATION The data on the label below matches the data on the label attached to the side of your insert.
  • Page 29: Optional Equipment

    PTIONAL QUIPMENT URROUND ANEL NSTALLATION EE TABLE BELOW FOR PART NUMBER Surround panel size is determined by the type of installation and the size of the fireplace opening. Direct and positive connections do not require insulation or panels that overlap the fireplace opening (panels that overlap the fireplace opening are usually more attractive).
  • Page 30: Insulation Installation

    PTIONAL QUIPMENT ONTINUED Insulation Installation The installation of the insulation is required only for face seal connections. Direct and positive connections do not require the insulation to be installed. 1. With the insert drawn 12" away from the fireplace, glue the insulation strip included with the surround panel kit to the back of the panels using RTV silicon or stove gasket cement.
  • Page 31: Front Blower Installation

    PTIONAL QUIPMENT ONTINUED RONT LOWER NSTALLATION 99000128) ART NUMBER The front blower is designed to improve the natural convection of the appliance by pushing air through the convection chamber of the appliance and causing the heated air to exit through the vents along the top of the appliance.
  • Page 32: Telescoping Leg Installation

    PTIONAL QUIPMENT ONTINUED ELESCOPING NSTALLATION 99200120) ART NUMBER The telescoping legs are designed to support the front end of fireplace inserts on raised hearths. It is adjustable from 4 5/8" to 7 1/2". It can be cut shorter by using a hacksaw (see the illustration below). 1.
  • Page 33: Flue Adapter Installation

    PTIONAL QUIPMENT ONTINUED DAPTER NSTALLATION 98900120) ART NUMBER The flue adapter has a built in flue collar with pre-drilled holes designed to make flue attachment easier. It may also be used to adjust the position of the flue exit. On inserts with surround panels, it may be used to offset the flue location up to 2 1/2"...
  • Page 34: Index

    NDEX Adjusting the Heat Output ..........14 Insert Size Requirements ..........7 Air Control Settings ............12 Insulation Installation (for panels) ........ 30 Ash Removal..............19 Leveling Bolt Installation ..........8 Baffle (removal and replacement) ........ 23 Listing Information............28 Block-Off Plate Installation ...........

Table of Contents