3-3-10. White Clip Level Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: MONITOR HD SDI 1 or 2 connector
Preparations
. Setting for MSU-900
MASTER GAIN → +12 dB
TEST1 button → ON (lit)
Adjustment Procedure
1. MSU menu operation:
. PAINT button → ON (lit)
. Touch panel operation
(Page 2/3) → [White|Clip]
Adjustment Item:
Adjust the levels A for preferred
level for R, G and B respectively.
To adjust all levels for R, G and B
simultaneously, adjust them using
the Master.
(Reference value: A = 756 mV)
Setting after Adjustment
. MASTER GAIN/MSU-900 → 0 dB
. TEST1 button/MSU-900 → OFF (dark)
F35
3-3-11. File Store
After adjustments described in Section 3-3 are completed,
be sure to execute the reference file store.
The settings after adjustments become the standard settings
(the state of being initialized with the standard buttons) of
the camera.
1. MSU menu operation:
. FILE button → ON (lit)
. Touch panel operation
[Reference] → [Ref|Store] → [Start]
2. When the store operation is completed, the message
"Completed" is displayed.
A
3-13