Operation And Cycle Information - Haier GE GDF510P M4 Series Service Manual

Plastic tub dishwasher
Table of Contents

Advertisement

This section of the guide provides details on segments of cycles, timing of cycles, temperature
expectations and cycling of the heater during the dry portion of a cycle.
Auto Hot Start
If incoming water temperature is below 75°F, Auto Hot Start is initiated at the beginning of the cycle
in an attempt to purge the home water lines of cooler water. Auto Hot Start can add up to 10 minutes
to overall cycle time. One Auto Hot Start segment includes a 1-minute fill, 1-minute circulate and
70-second drain, repeating this sequence if the 75°F temperature is not met. The dishwasher can
repeat this up to three times, if needed. If the temperature is met in one or two segments, the cycle
advances to the first prewash segment of the cycle.
Cycle Times
Times will vary depending on options selected, incoming water temperature, and soil level (on some
models).
Incoming water temperature of 120°F through 140°F is recommended.
The cycle chart below explains the segments of a cycle (cycles for all models included, some cycles
are only in select models). The chart below details fill and drain times which depend on either a full or
partial drain. It provides the circulation time in each segment, but does not include dry cycles (see the
Dry System section in this service guide). Times will vary depending on turbidity response (on some
models), options selected and water temperature.
Segment
Description
Fill (gal)
Circ (min)
PW1
Heat
Drain
Fill (gal)
Circ (min)
PW2
Heat
Drain
Fill (gal)
Circ (min)
PW3
Heat
Drain
Fill (gal)
Circ (min)
PW4
Heat
Drain
Fill (gal)
Main
Circ (min)
Wash
Heat
Drain
Fill (gal)
Circ (min)
PR1
Heat
Drain
Fill (gal)
Circ (min)
PR2
Heat
Drain
Fill (gal)
Final
Circ (min)
Rinse
Heat
Drain

Operation and Cycle Information

Cycle Algorithm Comparisons
Zonal
Diverter
Position
Use
Light
30LSA/
30USA
No
LSA
with
No
pulsing
60 LSA/
60 USA
No
60 LSA/
Yes
60 USA
Shorten
~30%
180 LSA/
Yes will
180 USA
Shorten
~30%
180 LSA/
Yes will
180 USA
Shorten
~30%
60 LSA/ 60
0.95
Yes will
USA
4
Shorten
No
~30%
Empty
60LSA/
0.95
120USA
5
No
No
Empty
Normal
Light
Heavy
Fixed
Soil
Soil
0.8
0.8
0.8
3
10
7
No
No
No
No Drain
Empty
Empty
0.8
10
No
Empty
0.8
5
No
Empty
0
0.8
0.8
20
40
40
Yes
Yes
Yes
Empty
Empty
Empty
0.9
12
No
Empty
0.8
0.8
0.8
4
4
4
Yes
No
No
Empty
Empty
Empty
0.8
0.8
0.8
15
15
15
Yes
Yes
Yes
Empty
Empty
Empty
– 9 –
AutoSense
1-hour/
Light
Heavy
Soil
Soil
Heavy
Express
0.8
0.8
0.8
10
7
7
No
No
No
Empty
Empty
Empty
Empty
0.8
0.8
10
10
No
No
Empty
Empty
Empty
0.8
0.8
5
5
No
No
Empty
Empty
0.8
15
Yes
Empty
0.8
0.8
0.8
45
45
45
Yes
Yes
Yes
Empty
Empty
Empty
Empty
0.9
0.9
0.9
12
12
12
No
No
Yes
Empty
Empty
Empty
Empty
0.8
0.8
0.8
5
5
4
No
No
No
Empty
Empty
Empty
Empty
0.9
0.9
0.9
30
30
30
Yes
Yes
Yes
Empty
Empty
Empty
Empty
0.8
4
No
0.9
4
No
0.9
17
Yes
0.9
4
No
0.9
4
No
0.9
9
Yes

Advertisement

Table of Contents
loading

Table of Contents