No Circulation And Drain - Haier GE GDF510P M4 Series Service Manual

Plastic tub dishwasher
Table of Contents

Advertisement

No Circulation and Drain

Circulation and Drain Pumps
will not run
Access main control, place dishwasher in Service
Mode, run circulation and drain tests. . Check for
120 VAC on connector J703 pin 3 (OX) to pin 4
(CX) for circulation pump and pin 1 (NX) to pin 2
(YX). Is there 120 VAC?
Diagnose drain pump, if drain pump checks OK,
Circulation pump is at fault. Replace Fuse and
inoperative Pump
Motors Fuse
A motors fuse is located on the main control board. If found open while testing for no circulation and
drain pump operation, the fuse and bad pump motor must be replaced. If 120 VAC is not present at
J703-3 to J703-4 for circulation pump or J703-1 to J703-2 for drain pump, remove and check the fuse
at the points shown in the below illustration. If an open fuse is found, replace the fuse and bad pump.
The drain pump can be diagnosed by removing connector J703 from the control and check the blue to
yellow wires using a multimeter on the highest resistance setting. If the reading is between 0.3 to 5.0
mega-ohm, then the drain pump is good. If it measures OL (overload or open), it indicates a bad drain
pump. If the drain motor checks OK, replace the circulation pump motor.
The circulation pump is a DC motor and cannot be checked for a resistance reading, it contains internal
diodes and rectifiers.
Is Fuse On Main
No
Control open?
Yes
Remove Sump Module to
Yes
check the AC wire harness
No
– 56 –
Open
Replace
OK
Harness
Replace
Main
Control
Pump Motors Fuse
Test Points