4.2.2
GMU 44B
The GMU 44B has one connector:
•
J442/P442 - 6-pin rectangular connector
4.2.3
GTP 59
The GTP 59 Temperature Probe does not have a connector. Rather, a 3-conductor shielded cable extends
from the sensor for interface with a GI 275.
Conductor Color
White
Blue
Orange
190-02246-C2
Rev. 3
Figure 4-4 J442/P442 Connector
Table 4-4 GMU 44B J442/P442 Connector
Pin
Function
1
SHIELD GROUND
2
RS-485 OUT B
3
RS-485 OUT A
4
POWER GROUND
5
RS-232 IN
6
MAG POWER INPUT
Table 4-5 GTP 59 3-Conductor Shielded Cable
Probe Power Lead
Resistive Element HI
Resistive Element LO
I/O
--
OUT
OUT
--
IN
IN
Name
GI 275 Part 27 AML STC Maintenance Manual
I/O
IN
OUT
OUT
Page 4-6