If no power supply is to be installed, install the filler panel into the power supply cage.

Installing and Removing the Server Board

Removing the Server Board

1. Disconnect all cables from the server board.
2. Remove the four screws to release the air duct side wall (see letter "A").
3. Lift the air duct side wall straight up to remove from the server board (see letter "B").
4. Remove the nine screws from the server board (see letter "C").
5. Lift the server board from the server system (see letter "D").
®
Intel
Server System R2000GZ/GL Service Guide

Figure 77. Installing the filler panel

Figure 78. Removing the Air Duct Side Wall